Modulation transfer function and optical quality after bilateral implantation of a +3.00 D versus a +4.00 D multifocal intraocular lens.
نویسندگان
چکیده
PURPOSE To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING Department of Ophthalmology, University of São Paulo, São Paulo, Brazil. DESIGN Prospective randomized double-masked comparative clinical trial. METHODS One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal + 3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.
منابع مشابه
Effect of position of near addition in an asymmetric refractive multifocal intraocular lens on quality of vision.
PURPOSE To evaluate the impact of the position of an asymmetric multifocal near segment on visual quality. SETTING Cathedral Eye Clinic, Belfast, United Kingdom. DESIGN Retrospective comparative case series. METHODS Data from consecutive patients who had bilateral implantation of the Lentis Mplus LS-312 multifocal intraocular lens were divided into 2 groups. One group received inferonasal...
متن کاملVisual outcomes and subjective experience after bilateral implantation of a new diffractive trifocal intraocular lens.
PURPOSE To assess clinical outcomes and subjective experience after bilateral implantation of a diffractive trifocal intraocular lens (IOL). SETTING Midland Eye Institute, Solihull, United Kingdom. DESIGN Cohort study. METHODS Patients had bilateral implantation of Finevision trifocal IOLs. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and manifest refractio...
متن کاملVisual and Optical Performances of Multifocal Intraocular Lenses with Three Different Near Additions: 6-Month Follow-Up
PURPOSE To compare the visual and optical outcomes of four multifocal intraocular lenses (IOLs) with three different near additions of +3.00 diopters (D), +3.75 D and +4.00 D. METHODS In this prospective study, 133 eyes of 88 patients were implanted with one of the following IOLs: AcrySof(®) ReSTOR(®) SN6AD1 (+3.00 D) for Group A, Acriva(UD) Reviol BB MF 613 or BB MFM 611 (+3.75 D) for Group ...
متن کاملHalo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses.
PURPOSE To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri +3.33 D, +1.66 D 839MP) were tested in vitro in a modified International Organization for Standar...
متن کاملMedium-Term Visual Outcomes of Apodized Diffractive Multifocal Intraocular Lens with +3.00 D Addition Power
Purpose. To evaluate 2-year visual acuities and questionnaire after bilateral implantation of SN6AD1 multifocal intraocular lens (MIOL) or SN60WF IOL. Methods. Patients randomly scheduled for bilateral implantation of SN6AD1 MIOL and SN60WF IOL with 2-year follow-up were enrolled. Uncorrected/corrected distance and near visual acuity, uncorrected intermediate visual acuity at 63 cm under high a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 38 2 شماره
صفحات -
تاریخ انتشار 2012