A comparison of three techniques to estimate the human dark-adapted cone electroretinogram

نویسندگان

  • Wayne A. Verdon
  • Marilyn E. Schneck
  • Gunilla Haegerstrom-Portnoy
چکیده

The dark-adapted cone electroretinogram (ERG) is difficult to isolate because of unwanted rod intrusion. We compare dark-adapted cone estimates derived using three techniques. The first uses the cone response on a moderate rod saturating background to estimate the dark-adapted cone response. The second uses red and blue flashes to tease apart cone and rod responses (red-minus-blue technique, [Investigative Ophthalmology and Visual Science 31 (1990) 2283]). The third uses a bright flash to temporarily saturate rods, followed by a test flash that generates a putative cone-only response (2-flash technique [Investigative Ophthalmology and Visual Science 36 (1995) 1603]). By subtracting the cone estimates from 'mixed' ERG responses in the dark, rod isolated responses can be derived. The rod phototransduction parameters, derived using a computational model, are similar using the light-adapted and 2-flash cone estimates, but differ using the red-minus-blue estimates. The 2-flash cone estimate gives a cone waveform similar to the dark-adapted response of a patient with Oguchi stationary night blindness (a patient with no rod ERG responses and normal cone ERG responses). The growth of the cone response during light adaptation to steady backgrounds causes significant differences between the light-adapted and 2-flash cone waveforms at times beyond the first few milliseconds.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the frequency characteristics of the electroretinogram signal in patients with central retinal vein occlusion

Background: Central retinal vein occlusion (CRVO) is the second most common retinal vascular disorder after diabetic retinopathy. In this study, we tried to examine the potentials of time-frequency methods for differentiating the eyes with CRVO. Materials and methods: Twenty patients with unilateral CRVO were included in this study. Their contralateral normal eyes were considered as the control...

متن کامل

Study of blue and red flash in dark-adapted electroretinogram.

PURPOSE To investigate the characteristics of the waveform generated by blue and red light stimulations in a dark-adapted electroretinogram (ERG) and those of cone responses in the dark-adapted condition. METHODS The study subjects were 52 persons (88 eyes) with no previous medical history. The author recorded b-waves (rod response) with red light stimulation and the x-waves (dark-adapted con...

متن کامل

Morphology of retinal photoreceptor layer in continuous light-exposed and dark-adapted male cats

The morphology of retinal photoreceptor layer was studied in continuous light-exposed and dark-adapteddomestic male cats (Felis catus). The eyes of 12 healthy adult cats (4 in continuous light-exposed group, 4 in continuous dark-adapted group, and 4 in control group) were routinely fixed and studied by electron microscope. Results showed that the general structure of photoreceptor layer in this...

متن کامل

Electroretinographically-determined scotopic spectral sensitivities of some marine fish.

INTRODUCTION BOTH BURKHARDT (1966) and WITKOVSKY (1968) used the electroretinogram to determine the dark-adapted spectral sensitivity of the gold&h and carp, respectively. They found that the b-wave was much more sensitive to long wavelengths than one would predict from the absorption spectrum of carp porphyropsin (CRESCITELLI and DARTNALL, 1954). They suggested that the cones were responsible ...

متن کامل

Rod-Driven OFF Pathway Responses in the Distal Retina: Dark-Adapted Flicker Electroretinogram in Mouse

PURPOSE The rodent retina does not exhibit a positive OFF-response in the electroretinogram (ERG), which makes it difficult to evaluate its OFF-pathway functions in vivo. We studied the rod-driven OFF pathway responses by using a dark-adapted 10-Hz flicker ERG procedure in mouse. MATERIALS AND METHODS Conventional ERGs and 10-Hz dark-adapted flicker ERGs were obtained in wild-type mice (C57BL...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2003