Efficient drug delivery to the lungs from a continuously operated open-vent nebulizer and low pressure compressor system.
نویسندگان
چکیده
A comparison of aerosol delivery has been made between two open-vent Pari jet nebulizers. Intermittent and continuous delivery were compared for one of the nebulizers. Ten healthy volunteers inhaled 99mTc-labelled diethylenetriamine penta-acetic acid (DTPA) aerosols on three occasions. The Pari LC device was operated both intermittently (by a manual interrupter that generated aerosol only in synchrony with inhalation) and continuously. The Pari LL nebulizer was operated only in the intermittent mode. A system of inspiratory and expiratory valves was fitted to each nebulizer in order to direct airflow. Both nebulizers were powered by Pari Boy compressors. The mean (SD) whole lung deposition for the LL nebulizer was 11.1 (4.0)% of the nominal dose, compared to 15.3 (12.8)% and 12.8 (7.9)% for the LC used with intermittent and continuous operation, respectively. These differences were not statistically significant. Regional deposition patterns within the lungs were similar for the three nebulizer systems. These data show that efficient nebulizer systems using relatively low power compressors are possible, and suggest that continuously operated open-vent nebulizers may be designed to give lung deposition comparable to that achieved by nebulizers fitted with manual interrupters.
منابع مشابه
Longitudinal evaluation of compressor/nebulizer performance.
BACKGROUND Inhaled medications are the mainstay of treatment for maintenance of lung health in patients with cystic fibrosis (CF). Compressor/nebulizer units are used an average of 100-120 min/d by patients with CF. Each compressor/nebulizer has unique flow/pressure characteristics that affect particle size distribution and drug output rate. Few data are available regarding longitudinal perform...
متن کاملBlow-by as potential therapy for uncooperative children: an in-vitro study.
BACKGROUND Blow-by, a common form of nebulizer therapy, in which the device is held away from a child's face, has been dismissed as ineffective because studies have demonstrated incremental aerosol drop-off with increasing distances from the face. Many of these studies do not take into account differences among nebulizer systems. Using common, commercially available nebulizer systems, we define...
متن کاملExtending the Performance of an Existing Breath-Actuated Nebulizer for Domiciliary Use: Initial Data
The AeroEclipse® BAN (Trudell Medical International (TMI), London, Canada) was initially developed for use in the hospital environment, optimized for medication delivery using air or oxygen supplied at 50 psig pressure (2, 3). This article describes initial laboratory data with a version (AeroEclipse-XL®) optimized for operation by either table-top (OmbraTM table-top compressor, TMI, 230V AC ve...
متن کاملOutput and aerosol properties of 5 nebulizer/compressor systems with arformoterol inhalation solution.
BACKGROUND Arformoterol, the (R,R) isomer of formoterol, is approved as an inhalation solution for the treatment of bronchoconstriction in patients with chronic obstructive pulmonary disease. Multiple nebulizer systems are commercially available. Different nebulizers can differ significantly in drug output, which may impact drug delivery and clinical efficacy. This study compared the aerosol pr...
متن کاملContinuous nebulization therapy for asthma with aerosols of beta2 agonists.
BACKGROUND Various studies have demonstrated the benefits of continuous nebulization therapy for delivering aerosols of the beta2 agonists such as terbutaline sulfate or albuterol sulfate to patients with severe asthma and/or impending respiratory failure. OBJECTIVE The purpose of this investigation was to explicate the operational factors associated with the use of nebulizers for extended ae...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 7 6 شماره
صفحات -
تاریخ انتشار 1994