Effect of bleaching on subsurface micro-hardness of composite and a polyacid modified composite.

نویسندگان

  • Christian Hannig
  • Sebastian Duong
  • Klaus Becker
  • Edgar Brunner
  • Elke Kahler
  • Thomas Attin
چکیده

OBJECTIVE To investigate the influence of different bleaching techniques on subsurface physical properties of composite and polyacid modified composite tested via determination of micro-hardness. METHODS Specimens of Tetric Flow, Tetric EvoCeram and Compoglass were light cured (2.5mm thickness) and stored in artificial saliva for 2 weeks (n=12/group). The samples were only removed for application of the following bleaching agents in a humid atmosphere: Either Vivastyle (1h/d), Whitestrips (30min/d), sodium-perborate-water mixture (once for 72h), Simply White (1h/d), or Opalescence XtraBoost (1st and 5th day for 15min) were applied on the surfaces of the samples. Untreated specimens served as negative controls, samples treated with ethyl alcohol for 1h acted as positive controls. After the bleaching period, samples were cross-sectioned and the micro-hardness (Knoop) of different subsurface levels (0.1mm-2.0mm) was determined. RESULTS All bleaching techniques significantly reduced the Knoop-hardness of the restoratives compared to untreated controls. Thereby, bleaching significantly affected not only superficial but also the deep layers of the specimens: in superficial layers (0.1mm, 0.2mm) lowest micro-hardness values amounted to 69.5% and 76.3% of the respective untreated controls (Compoglass/Vivastyle). In deeper subsurface levels, the lowest hardness was observed with Opalescence/Tetric EvoCeram (0.3mm: 78.3%; 0.4mm: 80%; 0.5mm: 80.5%; 1.0mm: 84.2%; 2.0mm: 84.4%). SIGNIFICANCE Bleaching with the tested bleaching agents softens the adhesive restorative materials examined. Due to the fact that subsurface layers are also affected, polishing of the surface may not suffice for re-establishing the physical properties of the surface of the fillings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microhardness of Esthetic Restorative Materials at Different Depths

The aim of this study was to analyze the microhardness of two resin-modified glass ionomer cements (Vitremer; Fuji II LC); two polyacid-modified composite resins (Freedom; F2000) and a hybrid composite resin (Prodigy), at different depths from the upper surface. Six hemi-cylinders (3 mm height; 3 mm radius) per tested material were obtained. Vickers Hardness was determined using a micro-indenta...

متن کامل

The effect of bleaching on microhardness of silorane-based composite resins

Introduction: Bleaching treatments may negatively affect the surface quality of composite restorations existing in the mouth. This study sought to assess the effect of 16% and 35% carbamide peroxide on microhardness of silorane-based versus two methacrylate-based composite resins. Methods: A total of 54 discs were fabricated from FiltekP90 (P90), FiltekZ350XT(Z350) Enamel and Filtek Z250(Z25...

متن کامل

مقایسه اثر رژیم‌های سفید‌کننده کاربامید پراکساید بر ریز‌سختی کامپوزیت Z250

Introduction: Bleaching products with oxidizing mechanism can exert side effects on the restorative materials existing in the oral cavity. Since bleaching agents are applied in different concentrations, the present study aimed to compare the effect of different bleaching regims of carbamide peroxide on microhardness of Z250 microhybride composite. Methods: In this in vitro study , 32 specime...

متن کامل

Surface hardness properties of resin-modified glass ionomer cements and polyacid-modified composite resins.

In this study the top and bottom surface hardness of two polyacid-modified composite resins (PMCRs), one resin-modified glass ionomer cement (RMGIC), and one composite resin were evaluated. The affect of water storage on their hardness was also investigated. The study was conducted using four different groups, each having five specimens obtained from fiberglass die molds with a diameter of 5 mm...

متن کامل

Size-dependent Bending of Geometrically Nonlinear of Micro-Laminated Composite Beam based on Modified Couple Stress Theory

In this study, the effect of finite strain on bending of the geometrically nonlinear of micro laminated composite Euler-Bernoulli beam based on Modified Couple Stress Theory (MCST) is studied in thermal environment. The Green-Lagrange strain tensor according to finite strain assumption and the principle of minimum potential energy is applied to obtain governing equation of motion and boundary c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dental materials : official publication of the Academy of Dental Materials

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 2007