Use of Platelet Function Testing Before Pipeline Embolization Device Placement: A Multicenter Cohort Study.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Thromboembolic complications constitute a significant source of morbidity after neurointerventional procedures. Flow diversion using the pipeline embolization device for the treatment of intracranial aneurysms necessitates the use of dual antiplatelet therapy to reduce this risk. The use of platelet function testing before pipeline embolization device placement remains controversial. METHODS A retrospective review of prospectively maintained databases at 3 academic institutions was performed from the years 2009 to 2016 to identify patients with intracranial aneurysms treated with pipeline embolization device placement. Clinical and radiographic data were analyzed with emphasis on thromboembolic complications and clopidogrel responsiveness. RESULTS A total of 402 patients underwent 414 pipeline embolization device procedures for the treatment of 465 intracranial aneurysms. Thromboembolic complications were encountered in 9.2% of procedures and were symptomatic in 5.6%. Clopidogrel nonresponders experienced a significantly higher rate of thromboembolic complications compared with clopidogrel responders (17.4% versus 5.6%). This risk was significantly lower in nonresponders who were switched to ticagrelor when compared with patients who remained on clopidogrel (2.7% versus 24.4%). In patients who remained on clopidogrel, the rate of thromboembolic complications was significantly lower in those who received a clopidogrel boost within 24 hours pre-procedure when compared with those who did not (9.8% versus 51.9%). There was no significant difference in the rate of hemorrhagic complications between groups. CONCLUSIONS Clopidogrel nonresponders experienced a significantly higher rate of thromboembolic complications when compared with clopidogrel responders. However, this risk seems to be mitigated in nonresponders who were switched to ticagrelor or received a clopidogrel boost within 24 hours pre-procedure.
منابع مشابه
Platelet Testing is Associated with Worse Clinical Outcomes for Patients Treated with the Pipeline Embolization Device.
BACKGROUND AND PURPOSE The necessity for platelet-inhibition testing before aneurysm treatment in patients premedicated with antiplatelet agents is controversial. Using the International Retrospective Study of Pipeline Embolization Device registry, we studied complication rates in groups of patients who underwent platelet testing and those who did not undergo platelet testing to determine if th...
متن کاملRisk Factors for Hemorrhagic Complications following Pipeline Embolization Device Treatment of Intracranial Aneurysms: Results from the International Retrospective Study of the Pipeline Embolization Device.
BACKGROUND AND PURPOSE Spontaneous intraparenchymal hemorrhage is a dreaded complication of unknown etiology following flow-diversion treatment. Using the International Retrospective Study of the Pipeline Embolization Device registry, we studied demographic, aneurysm, and procedural characteristics associated with intraparenchymal hemorrhage following Pipeline Embolization Device treatment. M...
متن کاملPipeline Embolization Device in the Treatment of Recurrent Previously Stented Cerebral Aneurysms.
BACKGROUND AND PURPOSE The use of the Pipeline Embolization Device in the management of recurrent previously stented cerebral aneurysms is controversial. The aim of this study was to evaluate the efficacy and safety of the Pipeline Embolization Device in the treatment of recurrent, previously stented aneurysms. MATERIALS AND METHODS Twenty-one patients with previously stented recurrent aneury...
متن کاملRandomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts.
BACKGROUND Stents provide effective treatment for stenotic saphenous venous aorto-coronary bypass grafts, but their placement carries a 20% incidence of procedure-related complications, which potentially are related to the distal embolization of atherosclerotic debris. We report the first multicenter randomized trial to evaluate use of a distal embolic protection device during stenting of such ...
متن کاملFlow Diverter Therapy With the Pipeline Embolization Device Is Associated With an Elevated Rate of Delayed Fluid-Attenuated Inversion Recovery Lesions.
BACKGROUND AND PURPOSE Flow diversion using the Pipeline Embolization Device is reported as a safe treatment of aneurysms. Complete aneurysm occlusion, however, occurs in a delayed fashion with initial persistent filling of the aneurysm dome. We hypothesized that this transflow across metallic struts may be associated with thromboembolic events. METHODS Forty-one consecutive patients undergoi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 48 5 شماره
صفحات -
تاریخ انتشار 2017