LC Note: LC-TOOL-2004-019 arXiv:physics/0409040 COMPARISONS OF HADRONIC SHOWER PACKAGES
نویسنده
چکیده
We report on simulation studies comparing various hadronic shower packages. Results show that predictions from different models vary significantly, illustrating the necessity of testbeam data to resolve the situation. We report on simulation studies comparing various hadronic shower packages. Results show that predictions from different models vary significantly, illustrating the necessity of testbeam data to resolve the situation.
منابع مشابه
LC Note: LC-TOOL-2004-020 arXiv:physics/0409039 CALORIMETER CLUSTERING WITH MINIMAL SPANNING TREES
We present a top-down approach to calorimeter clustering. An algorithm based on minimal spanning tree theory is described briefly. We present a top-down approach to calorimeter clustering. An algorithm based on minimal spanning tree theory is described briefly.
متن کاملComparisons of Hadronic Shower Packages
The high precision measurements needed to exploit the physics potential of an ee Future Linear Collider with 0.5 1 TeV center-of-mass energy range set strict requirements on performance of vertex, tracking and calorimetric detectors. The CALICE Collaboration [1] has been formed to conduct the research and development effort needed to bring initial conceptual designs for the calorimetry to a fin...
متن کاملLow-Energy Hadronic Interaction Models
Different interaction models treating hadronic collisions below Elab<100 GeV in air shower simulations are compared within the frame of the CORSIKA program. Their behaviour is studied in isolated collisions of protons or pions with light-mass targets in comparison with experimental data. It is discussed how model properties influence air-shower parameters like the longitudinal profile or the la...
متن کاملPolyAlign: A Versatile LC-MS Data Alignment Tool for Landmark-Selected and -Automated Use
We present a versatile user-friendly software tool, PolyAlign, for the alignment of multiple LC-MS signal maps with the option of manual landmark setting or automated alignment. One of the spectral images is selected as a reference map, and after manually setting the landmarks, the program warps the images using either polynomial or Hermite transformation. The software provides an option for au...
متن کاملFast screening of mobile and stationary phases with the Agilent 1290 Infinity LC and seamless method transfer to an Agilent 1200 Series LC using ISET
This Application Note describes how the Agilent 1290 Infinity LC System Method Development Solution was used to find optimum separation conditions for degradation products of a pharmaceutical preparation. Having evaluated the optimum combination, a transfer to conventional conditions was performed. Finally, the Agilent Intelligent System Emulation Technology (ISET) of the 1290 Infinity LC was u...
متن کامل