Influence of cervical finish line type on the marginal adaptation of zirconia ceramic crowns.

نویسندگان

  • Muharrem Comlekoglu
  • Mine Dundar
  • Mutlu Ozcan
  • Mehmet Gungor
  • Bulent Gokce
  • Celal Artunc
چکیده

The current study evaluated the effect of different cervical finish line designs on the marginal adaptation of a zirconia ceramic. Four different marginal finish lines (c: chamfer, mc: mini-chamfer, fe: feather-edge and s: rounded shoulder) were prepared on phantom incisors. Die models for each preparation group (N = 28, n = 7 per finish line design group) were made of epoxy resin. Y-TZP (ICE Zirkon) frameworks were manufactured by a copy-milling system (Zirconzahn) using prefabricated blanks and tried on the master models for initial adaptation of the framework; they were then sintered, followed by veneering (Zirconzahn). The finished crowns were cemented with a polycarboxylate cement (Poly F) under 300 g load and ultrasonically cleaned. The specimens were sliced and the marginal gap was measured, considering absolute marginal opening (AMO) and marginal opening (MO) for each coping under a stereomicroscope with image processing software (Lucia). The measurements were statistically analyzed using the Kruskal Wallis, Mann Whitney and Wilcoxon Signed Ranks tests at a significance level of alpha = 0.01. Means of AMO measurement (microm) for the feather-edge finish line (87 +/- 10) was significantly lower than that of the chamfer (144 +/- 14), shoulder (114 +/- 16) and mini-chamfer finish line types (114 +/- 11) (p < 0.01). Means of MO measurements was the lowest for feather-edge finish line (68 +/- 9) (p < 0.01) and then, in ascending order, shoulder (95 +/- 9), mini-chamfer (97 +/- 12) and chamfer (128 +/- 10). The cervical finish line type had an influence on the marginal adaptation of the tested zirconia ceramic. Although the feather-edge finish line resulted in lower AMO and MO values, with its proven mechanical disadvantage, it cannot be recommended in clinical applications of zirconia crowns. This type of finish line has acted solely as a control group to test the null hypothesis in the current study. For better marginal adaptation, both shoulder and mini-chamfer finish line types could be suggested for zirconia crowns.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Different Finishing Lines on the Marginal Fitness of Full Contour Zirconia and Glass Ceramic CAD/CAM Crowns (An in-vitro study)

Purpose: The aim of this study was to evaluate the effect of two gingival finishing lines (90° shoulder and deep chamfer) on the marginal fitness of two types of full anatomic all-ceramic crowns; zirconia crowns (Zikonzhan) and glass ceramic crowns (IPS e-max CAD) milled with CAD/CAM system. Materials and Methods: Two dentoform teeth of left maxillary first molar were prepared with chamfer fini...

متن کامل

The Effect of Preparation Design on the Marginal Integrity of Monolithic Zirconia Crown

Abstract Background & Aim: Marginal adaptation of full ceramic zirconia restorations are one of the important factors in their long-term success and one of the factors affecting marginal adaptation and their strength is the finish line design.This study was conducted to compare the effect of finishline design on the adaptation of monolithic zirconia crowns. Material and methods: In this in-vitr...

متن کامل

The Effect of Different Marginal Designs on the Fracture Resistance of Monolithic Zirconia Crowns

Abstract   Background and Aim: One of the major problems of all ceramic restorations is their probable fracture against the occlusal force. The aim of the present in vitro study is to compare the effect of three marginal designs (shoulder, sloped shoulder, chamfer) on the fracture resistance of monolithic zirconia crowns. Materials and methods: In this in vitro study, three PEEK dies with cham...

متن کامل

Effect of Core Thickness and Porcelain Sintering on Marginal Adaptation

Background and aim: Marginal adaptation affects the long-term success of full-coverage restorations. This study aimed to assess the effect of porcelain sintering and zirconia core thickness on the marginal adaptation of all-ceramic restorations. Materials and methods: In this in-vitro experimental study, a standard brass die, 7 mm in length and 5 mm in diameter, was fabricated using a milling ...

متن کامل

The Effect of Porcelain Firing and Type of Finish Line on the Marginal Fit of Zirconia Copings

STATEMENT OF THE PROBLEM Although all-ceramic restorations are broadly used, there is a lack of information concerning how their fit is affected by fabrication procedure and marginal configuration. PURPOSE The purpose of this study was to evaluate the marginal fit of zirconia CAD/CAM ceramic crowns before and after porcelain firing. The influence of finish line configuration on the marginal f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Operative dentistry

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2009