Microbiologic assessment of disposable sterile endoscopic sheaths to replace high-level disinfection in reprocessing: a prospective clinical trial with nasopharygoscopes.

نویسندگان

  • Carla J Alvarado
  • Ashley G Anderson
  • Dennis G Maki
چکیده

BACKGROUND Conventional reprocessing of endoscopes with high-level disinfection is labor intensive, expensive, delays the turnover of instruments, and involves potential exposure of personnel to toxic chemicals. We report a prospective clinical trial with rigorous microbiologic assessment of a novel disposable, sterile, polyurethane sheath, which can be easily and snugly applied over a nasopharyngoscope before performing the endoscopic procedure, with enzymatic cleansing and disinfection of the instrument with 70% ethanol following the procedure to determine whether the use of the novel sheath can provide reliable protection against bacterial contamination and obviate the need for routine high-level disinfection in reprocessing. METHODS Baseline cultures were obtained at 3 time periods from the control heads and insertion shafts of nasopharyngoscopes used in 100 clinical examinations: before application of the protective sheath and execution of the procedure; immediately after the procedure and removal of the sheath; and after enzymatic cleaning, disinfection with 70% ethanol, and drying. All 100 used sheaths and 20 unused sheaths were subjected to high-pressure leak testing to assess barrier integrity. RESULTS Bacteria were detected on 16 control heads and 6 shafts prior to the procedure; from 13 heads and 1 shaft immediately following the nasopharyngoscopic procedure and sterile sheath removal; and none of the instruments following cleaning, ethanol disinfection, and drying. No sheath showed loss of barrier integrity on leak testing. CONCLUSION Use of a high-quality, snugly fitting, sterile, disposable polyurethane sheath on a nasopharyngoscope during a clinical examination, combined with enzymatic detergent cleaning and disinfection with 70% ethanol, can provide a reliably decontaminated, patient-ready instrument, eliminating the need for high-level disinfection of endoscopes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A microbiological evaluation of level of disinfection for flexible cystoscopes protected by disposable endosheaths

BACKGROUND Flexible cystoscopy is used in urological outpatient departments for diagnostic cystoscopy of bladder cancer and requires a high-level disinfection between each patient. The purpose of this study was to make a microbiological post disinfection efficacy assessment of flexible cystoscopes (FC) using disposable sterile endosheaths. METHODS One hundred endosheaths underwent a leak-test...

متن کامل

Gastrointestinal endoscopes: a need to shift from disinfection to sterilization?

More than 10 million gastrointestinal endoscopic procedures areperformedannually in theUnitedStates fordiagnosticpurposes, therapeutic interventions, or both.1 Because gastrointestinalendoscopescontactmucosal surfaces,useofacontaminated endoscope may lead to patient-to-patient transmission of potential pathogens with a subsequent risk of infection.1 In this issue of JAMA, Epstein and colleagues...

متن کامل

Reprocessing endoscopes: United States perspective.

Endoscopes are used frequently for the diagnosis and therapy of medical disorders. For example, greater than 10000000 gastrointestinal endoscopic procedures are performed each year in the United States. Failure to employ appropriate cleaning and disinfection/sterilization of endoscopes has been responsible for multiple nosocomial outbreaks and serious, sometimes life-threatening, infections. Fl...

متن کامل

Steps of Reprocessing and Equipments

With the increasing interest in endoscopy and the rising number of endoscopic examinations in hospitals, the importance of endoscopic reprocessing is also increasing. Cure facilities that are understaffed and ill-equipped are trying to cope with the problems of insufficient cleaning and high infection risks. To prevent endoscopy-associated infection, the endoscope cleaning, and disinfection gui...

متن کامل

A performance, safety and cost comparison of reusable and disposable endoscopic biopsy forceps: a prospective, randomized trial.

BACKGROUND Many gastroenterologists believe that disposable forceps are more expensive than reusable forceps. It has been shown, however, that cross contamination and spread of infection are possible with reusable forceps. We conducted a prospective, randomized study to evaluate the performance, safety and cost of reusable versus disposable biopsy forceps. METHODS Endoscopists were randomly a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of infection control

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2009