Collision-induced dissociation of lanthanide oxide ions in quadrupole ion traps: effects of bond strength and mass
نویسندگان
چکیده
Collision-induced dissociation (CID) rates are measured for a suite of lanthanide (plus yttrium) monoxide ions stored in a quadrupole ion trap. Yttrium, neodymium, and gadolinium oxides, having the same nominal dissociation energy (D0 ≈ 735 kJ mol−1) but different masses, provide an empirical correction of −1.2 s−1 amu−1 for the measured CID rates. The CID rate correction enables the correlation of bond dissociation energy with CID rate, allowing quantitative determinations of bond dissociation energies for lanthanide metal monoxide ions. For bond dissociation energies in the range of 567–849 kJ mol−1, mass corrected rates range from 50 to 120 s−1. The calibration sensitivity is equivalent to 5 kJ mol−1 s−1, and the measurement precision is ∼25 kJ mol−1. Bond energy determinations are found to agree with the average values reported for lanthanide oxide ions. (Int J Mass Spectrom 216 (2002) 85–93) © 2002 Elsevier Science B.V. All rights reserved.
منابع مشابه
Dynamic collision-induced dissociation of peptides in a quadrupole ion trap mass spectrometer.
The fragmentation of natural peptides using dynamic collision-induced dissociation (DCID), a novel fragmentation method for quadrupole ion traps, is demonstrated. Using leucine enkephalin as a diagnostic molecule, the fragmentation efficiencies and energetics of DCID are compared with other methods of collisional activation in ion traps such as conventional on-resonance excitation and high-ampl...
متن کاملThreshold collision-induced dissociation measurements using a ring ion guide as the collision cell in a triple-quadrupole mass spectrometer.
A triple-quadrupole mass spectrometer has been modified for bond-dissociation energy measurements via threshold collision-induced dissociations (TCIDs) by replacing the conventional collision cell with a ring ion guide. Optimal operating conditions for the ring ion guide were determined or derived, and validated using a set of complexes for which bond dissociation energies are known. A comparis...
متن کاملIon activation methods for tandem mass spectrometry.
This tutorial presents the most common ion activation techniques employed in tandem mass spectrometry. In-source fragmentation and metastable ion decompositions, as well as the general theory of unimolecular dissociations of ions, are initially discussed. This is followed by tandem mass spectrometry, which implies that the activation of ions is distinct from the ionization step, and that the pr...
متن کاملEfficient polyatomic interference reduction in plasma-source mass spectrometry via collision induced dissociation{
Evidence is provided that illustrates quadrupole ion traps can be used to selectively attenuate strongly bound diatomic ions occurring at the same nominal mass as an analyte ion of interest. Dissociation rates for TaO (D0 y 750 kJ mol ) are found to be at least an order of magnitude larger than the loss rate of Au due to scattering under ‘‘slow heating’’ resonance excitation conditions at qz ~ ...
متن کاملGas-phase reactions of bare and oxo-ligated actinide and lanthanide cations with pentamethylcyclopentadiene studied in a quadrupole ion trap mass spectrometer
Reactions of bare and oxo-ligated monopositive ions of uranium and thorium with 1,2,3,4,5-pentamethylcyclopentadiene, C10H16, (HCp∗) were examined in a quadrupole ion trap (QIT) mass spectrometer. Representative lanthanide ions, Ln+ and LnO+, and tantalum ions, Ta+ and TaO+, were studied for comparison. The product branching ratios for both primary and secondary reactions of the actinide ions d...
متن کامل