Ultrastructural changes of human trabecular meshwork after photocoagulation with a diode laser.

نویسندگان

  • D Mchugh
  • J Marshall
  • T J Ffytche
  • P A Hamilton
  • A Raven
چکیده

A diode laser, which emitted infrared radiation at a wavelength of 810 nm, was used to perform trabecular photocoagulation in a human eye due for enucleation for malignant melanoma. For comparison, burns were applied with an argon blue-green laser (488-514.5 nm). With each laser, the treatment spot size was 100 microns and the pulse duration was 0.20 sec. Visible lesions were produced with a power of between 750 mW and 1.2 W with the diode laser, and 500-900 mW with the argon laser. The pattern of damage produced by both modalities was similar and essentially consisted of contraction or expansion of trabecular beams, with trabecular destruction occurring only in relation to high power exposures. These findings confirm that trabecular photocoagulation is not a process that depends upon the wavelength of the incident energy at the two spectral extremes of 488 nm and 810 nm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ulfrasfrucfural Changes of Human Trabecular Meshwork After Phofocoagulation With a Diode Laser

A diode laser, which emitted infrared radiation at a wavelength of 810 nm, was used to perform trabecular photocoagulation in a human eye due for enucleation for malignant melanoma. For comparison, burns were applied with an argon blue-green laser (488-514.5 nm). With each laser, the treatment spot size was 100 nm and the pulse duration was 0.20 sec. Visible lesions were produced with a power o...

متن کامل

Ultrastructural Changes in Human Trabecular Meshwork Tissue after Laser Trabeculoplasty

Purpose. To compare morphologic changes in human trabecular meshwork (TM) after selective laser trabeculoplasty (SLT) and argon laser trabeculoplasty (ALT). Design. Laboratory evaluation of ex vivo human eye TM after laser trabeculoplasty. Methods. Corneoscleral rims from human cadaver eyes were sectioned and treated with varying powers of either SLT or ALT. Specimens were examined using light ...

متن کامل

A Laser-Induced Mouse Model with Long-Term Intraocular Pressure Elevation

PURPOSE To develop and characterize a mouse model with intraocular pressure (IOP) elevation after laser photocoagulation on the trabecular meshwork (TM), which may serve as a model to investigate the potential of stem cell-based therapies for glaucoma. METHODS IOP was measured in 281 adult C57BL/6 mice to determine normal IOP range. IOP elevation was induced unilaterally in 50 adult mice, by ...

متن کامل

Histopathologic and ultrastructural findings of photocoagulation lesions produced by transpupillary diode laser in the rabbit retina.

Transpupillary retinal photocoagulations were performed on ten eyes of five pigmented rabbits using a diode laser (Nidek Co., LTD, Aichi, Japan) emitting infrared radiation at 800 nm wavelength. A histological and an ultrastructural study on the treated eyes were done at 1, 3, 5, and 7 days after retinal photocoagulations. The purpose of this study was to observe the sequential changes in the r...

متن کامل

Translimbal laser photocoagulation to the trabecular meshwork as a model of glaucoma in rats.

PURPOSE To develop and characterize a model of pressure-induced optic neuropathy in rats. METHODS Experimental glaucoma was induced unilaterally in 174 Wistar rats, using a diode laser with wavelength of 532 nm aimed at the trabecular meshwork and episcleral veins (combination treatment group) or only at the trabecular meshwork (trabecular group) through the external limbus. Intraocular press...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 33 9  شماره 

صفحات  -