Red cell survival after aortic valve replacement with Björk-Shiley prosthesis in presence of sickle-cell trait.

نویسندگان

  • P W Wenham
  • G L Scott
  • J D Wisheart
چکیده

A case of aortic valve replacement with a Björk-Shiley disc prosthesis in a patient with sickle-cell trait is presented. Six months after operation red cell survival was not significantly reduced. On theoretical and clinical grounds it is concluded that the presence of sickle-cell trait does not contribute to late postoperative haemolysis after heart valve replacement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis. Clinical experiences in 50 cases.

Single aortic valve replacement with the Björk-Shiley tilting disc valve prosthesis has been performed in 50 patients since April 1971. None of the total of six deaths (12.0%) was attributable to malfunction of the prosthesis or to embolic complications. Follow-up examination showed insignificant or moderate prosthetic regurgitation in two patients and moderate paravalvular leakage in one patie...

متن کامل

Haemolysis after mitral valve replacement with the Björk-Shiley and the Lillehei-Kaster disc valve prosthesis.

The present study reports on the incidence and degree of intravascular haemolysis in 33 patients with Björk-Shiley tilting disc prosthesis and in 34 patients with Lillehei-Kaster pivoting disc valve prosthesis in the mitral position examined 12 to 24 months after the operation. Serum haptoglobin, serum lactate dehydrogenase, serum bilirubin, and haemoglobin estimations were performed. Significa...

متن کامل

Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.

Seventy-four patients with single prosthetic valves (Björk-Shiley or Starr-Edwards) in the mitral or aortic position and 18 controls with rheumatic valvar heart disease were investigated for evidence of intravascular haemolysis. Serum lactate dehydrogenase (LDH) was used as the most sensitive indicator of haemolysis. Raised concentrations were found in a third of 39 patients with Björk-Shiley p...

متن کامل

Age thresholds for prophylactic replacement of Björk-Shiley convexo-concave heart valves. A clinical and economic evaluation.

BACKGROUND Björk-Shiley convexo-concave heart valves have an increased risk of mechanical failure. One might consider prophylactic rereplacement as a preventive measure to avert the disastrous consequences of these failures. We investigated the effect that prophylactic rereplacement has on survival of individual patients and on the medical costs. METHODS AND RESULTS Quantitative estimates for...

متن کامل

Hemodynamics alterations induced by isoproterenol and pacing after aortic valve replacement with the Björk-Shiley or St. Jude medical prosthesis.

Stress evaluation was carried out in 26 patients approximately 7 months after aortic valve replacement with Björk-Shiley valves (13 patients) and St. Jude medical valves (13 patients). During isoproterenol infusion (0.3 micrograms/kg/min), cardiac output increased by a factor of 1.5 and aortic valve area decreased by 50% for both valve groups, while transvalvular gradients (rest: 7 +/- 2 vs 10 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 40 6  شماره 

صفحات  -

تاریخ انتشار 1978