Analyzing Thorough QT Study 1 & 2 in the Telemetric and Holter ECG Warehouse (THEW) using Hannover ECG System HES : A validation study.
نویسندگان
چکیده
Following the ICH E14 clinical evaluation guideline [1], the measurement of QT/QTc interval prolongation has become the standard surrogate biomarker for cardiac drug safety assessment and the faith of a drug development. In Thorough QT (TQT) study, a so-called positive control is employed to assess the ability of this study to detect the endpoint of interest, i.e. the QT prolongation by about five milliseconds. In other words the lower bound of the one-sided 95% confidence interval (CI) must be above 0 [ms]. Fully automated detection of ECG fiducial points and measurement of the corresponding intervals including QT intervals and RR intervals vary between different computerized algorithms. In this work we demonstrate the ability and reliability of Hannover ECG System (HES(®)) to assess drug effects by detecting QT/QTc prolongation effects that meet the threshold of regulatory concern as mentioned by using THEW database studies namely TQT studies one and two.
منابع مشابه
A unique digital electrocardiographic repository for the development of quantitative electrocardiography and cardiac safety: the Telemetric and Holter ECG Warehouse (THEW).
The sharing of scientific data reinforces open scientific inquiry; it encourages diversity of analysis and opinion while promoting new research and facilitating the education of next generations of scientists. In this article, we present an initiative for the development of a repository containing continuous electrocardiographic information and their associated clinical information. This inform...
متن کاملA Unified Framework for Delineation of Ambulatory Holter ECG Events via Analysis of a Multiple-Order Derivative Wavelet-Based Measure
In this study, a new long-duration holter electrocardiogram (ECG) major events detection-delineation algorithm is described which operates based on the false-alarm error bounded segmentation of a decision statistic with simple mathematical origin. To meet this end, first three-lead holter data is pre-processed by implementation of an appropriate bandpass finite-duration impulse response (FIR) f...
متن کاملDifferences in the Slope of the QT-RR Relation Based on 24-Hour Holter ECG Recordings between Cardioembolic and Atherosclerotic Stroke
Objective Detecting paroxysmal atrial fibrillation in patients with ischemic stroke presenting in sinus rhythm is difficult because such episodes are often short, and they are also frequently asymptomatic. It is possible that the ventricular repolarization dynamics may reflect atrial vulnerability and cardioembolic stroke. Hence, we compared the QT-RR relation between cardioembolic stroke and a...
متن کاملClinical Evaluation of a Mobile Heart Rhythm Telemonitoring System
Purpose. To evaluate the clinical applicability of a telemonitoring system: telemetric system for collection and distant surveillance of medical information (TEMEO). Methods. We evaluated 60 patients, applying simultaneously standard Holter ECG and telemonitoring. Two different comparisons were performed: (1) TEMEO ECG with standard 12-lead ECG; (2) TEMEO Holter with standard ECG Holter. Result...
متن کاملHeritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs
INTRODUCTION The resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters. MET...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computing in cardiology
دوره 37 شماره
صفحات -
تاریخ انتشار 2010