Performance of point-of-care diagnosis of AIDS: label-free one-step-immunoassay vs. lateral flow assay.

نویسندگان

  • J-H Kwon
  • H-T Kim
  • S J Sim
  • Y J Cha
  • J Lee
چکیده

The objective of this study is to develop an accurate, rapid, simple, and label-free assay technology that enables point-of-care diagnosis of AIDS. For this, 3-dimensional (3D) probes to sensitively detect anti-HIV antibodies were designed and synthesized by genetically presenting a HIV antigen (gp41) on the surface of engineered human ferritin nanoparticles. The 3D probes also present multi-copies of the hexa-histidine peptide (H6) on their surface to chemisorb gold ions (Au3+), which is essential for the generation and self-enhancement of assay signals. The developed new assay technology (named "one-step-immunoassay") quickly produced clear optical signals through a simple and convenient one-step procedure. The diagnostic performance of the one-step-immunoassay was compared with that of the conventional lateral flow assay (LFA) using 30 AIDS patient and 20 healthy sera. The sensitivity of LFA was only 63% when a single antigen (gp41) was used but enhanced to 90% when three different antigens (gp41, p24, and gp120) were used together as the assay probes. In contrast, the one-step-immunoassay using only gp41 produced strong optical signals within 15 min without causing any false negative/positive signals, showing 100% sensitivity and 100% specificity and holding promising potential for clinical point-of-care diagnosis of AIDS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An interference-free and rapid electrochemical lateral-flow immunoassay for one-step ultrasensitive detection with serum.

Point-of-care testing (POCT) of biomarkers in clinical samples is of great importance for rapid and cost-effective diagnosis. However, it is extremely challenging to develop an electrochemical POCT technique retaining both ultrasensitivity and simplicity. We report an interference-free electrochemical lateral-flow immunoassay that enables one-step ultrasensitive detection with serum. The electr...

متن کامل

A fast and sensitive immunoassay of avian influenza virus based on label-free quantum dot probe and lateral flow test strip.

A novel fluorescence immunoassay method for fast and ultrasensitive detection of avian influenza virus (AIV) was developed. The immunoassay method which integrated lateral flow test strip technique with fluorescence immunoassay used the label-free and high luminescent quantum dots (QDs) as signal output. By the sandwich immunoreaction performed on lateral flow test strip, the gold nanoparticle ...

متن کامل

Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies

Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...

متن کامل

INTEGRATED ASSAY WITH SAMPLE PROCESSING: PAPER-BASED DEVICE FOR IgM DETECTION

Point-of Care (POC) devices that can perform multi-step processes, are easy to use, and are inexpensive, are needed for use in limited-resource settings. We present an integrated paper-based device that performs an automated immunoassay for the detection of IgM antibodies with on-board sample processing. The device is a two-dimensional paper network (2DPN) consisting of protein-G coated nitroce...

متن کامل

DETERMINATION OF SERUM CORTISOL LEVEL BY A DIREC T ENZYME IMMUNOASSAY USING PENICILLINASE AS LABEL

Serum cortisol level was measured by an enzyme immunoassay (EIA) using the enzyme penicillinase as a label without prior extraction and purification. Polyclonal antibodies were raised against cortisol-3-ortho-carboxymethyl-oxime (cortisol-3-0-CMO) conjugated to bovine serum albumin (BSA). This antibody showed a very low cross-reactivity with structurally related steroids (3.7% for corticos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 143 4  شماره 

صفحات  -

تاریخ انتشار 2018