PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet.
نویسندگان
چکیده
PURPOSE To prospectively use compact avalanche photodiodes instead of photomultiplier tubes to integrate a positron emission tomographic (PET) detector and a 7-T magnetic resonance (MR) imager. MATERIALS AND METHODS All animal experiments were performed in accordance with the University of Tübingen guidelines and the German law for the protection of animals. A compact lutetium oxyorthosilicate-avalanche photodiode PET detector was built and optimized to operate within a 7-T MR imager. The detector performance was investigated both outside and inside the magnet, and MR image quality was evaluated with and without the PET detector. Two PET detectors were set up opposite each other and operated in coincidence to acquire PET images in the step-and-shoot mode in a mouse head specimen after injection of fluorine 18 fluorodeoxyglucose. RESULTS The performance of the PET detector when operated inside the magnet during MR image acquisition showed little degradation in energy resolution (increase from 14.6% to 15.9%). The PET detector did not influence MR imaging. The fused PET and MR images showed an anatomic match and no degradation of image quality. CONCLUSION Simultaneous PET and MR imaging with a 7-T system was deemed feasible.
منابع مشابه
Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.
UNLABELLED PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. METHODS The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode ...
متن کاملDevelopment of PET insert for simultaneous PET/MR imaging of human brain
Molecular Imaging Research & Education (MiRe) Laboratory, Department of Electronic Engineering, Sogang University, Seoul, Korea Recently, there has been great interest on the development of combined PET/MR, which is a useful tool for both functional and anatomic imaging. The purpose of this study was to develop a MR compatible PET insert for simultaneous PET and MR imaging of human brain and to...
متن کاملEffects of Magnetic Fields of up to 9.4 T on Resolution and Contrast of PET Images as Measured with an MR-BrainPET
Simultaneous, hybrid MR-PET is expected to improve PET image resolution in the plane perpendicular to the static magnetic field of the scanner. Previous papers have reported this either by simulation or experiment with simple sources and detector arrangements. Here, we extend those studies using a realistic brain phantom in a recently installed MR-PET system comprising a 9.4 T MRI-scanner and a...
متن کاملDevelopment of an MR-compatible DOI-PET detector module
Department of Electrical Engineering, Tsinghua University, Beijing, China Silicon Photomultiplier (SiPM) is a promising sensor for MR-compatible PET systems. In this paper, we developed a compact 2-layer DOI-PET detector. The top layer is a 15Ã15 LYSO array, and the crystal size is 2x2x7mm. The bottom layer is a 16Ã16 array with the same size crystals. There is half-crystal offset between two l...
متن کاملSimultaneous PET and MR imaging.
We have developed a prototype PET detector which is compatible with a clinical MRI system to provide simultaneous PET and MR imaging. This single-slice PET system consists of 48 2 x 2 x 10 mm3 LSO crystals in a 38 mm diameter ring configuration that can be placed inside the receiver coil of the MRI system, coupled to three multi-channel photomultipliers housed outside the main magnetic field vi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 244 3 شماره
صفحات -
تاریخ انتشار 2007