Expiratory limb ventilation during anesthesia machine failure.
نویسنده
چکیده
987 October 2013 To the Editor: I read with interest the case report by Seif and Olympio,1 who described the successful use of expiratory limb ventilation during a ventilatory emergency when removal of the absorbent canister from a GE Aestiva/5 anesthesia machine (GE Healthcare, Mickleton, NJ) resulted in a large leak in the circle breathing system. The authors note that with their arrangement it is unlikely that fresh machine anesthetic gas and oxygen would flow antegrade during exhalation, rather than it would take the path of least resistance to flow retrograde and out through the leak. In the event where such a ventilatory crisis should recur, I would like to suggest an alternative arrangement for expiratory limb ventilation that allows the use of fresh gas flow from the machine (flowmeters and vaporizer) and does not require that the self-inflating manual ventilation device be connected to an oxygen source. The GE Aestiva/5 machine incorporates an auxiliary common gas outlet (ACGO), which is used to perform the machine low-pressure system leak check or to connect other breathing circuits such as the Bain. When the green lever (fig. 1) is depressed, fresh gas from the machine is diverted (from its usual path into the circle system via the inspiratory limb connection port; fig. 1) to flow instead out from the ACGO (fig. 1C). In the above crisis scenario, the inspiratory limb of the circle system would be connected to the selected ACGO, delivering fresh gas and agent from the machine, and the self-inflating manual ventilation device is connected to the end of the expiratory limb of the circuit (fig. 1). Connection of the self-inflating manual ventilation device to an oxygen source is now unnecessary because oxygen is delivered in the fresh gas flow from the ACGO. Furthermore, if an inhaled anesthetic is being administered, waste gas scavenging could be achieved by placing a 30–19 mm adapter over the (30 mm diameter) exhalation port of the self-inflating manual ventilation device and connecting the 19 mm end to scavenging tubing. The arrangement described could be used with any anesthesia machine that has an integral ACGO (e.g., GE Aespire [GE Healthcare, Mickleton, NJ] some GE Aisys Carestations [GE Healthcare, Mickleton, NJ]) or a regular common gas outlet that has a 22 mm external diameter (e.g., GE ADU workstation [GE Healthcare, Mickleton, NJ]). In some models of GE workstations (e.g., Aisys Carestation), the inspiratory connection port of the circle system can be converted to a common gas outlet by selecting “Non Circle System” from the screen menu. I should point out that not all anesthesia machine manufacturers offer models that have an ACGO. However, anesthesia caregivers should check if their machine(s) has (have) this feature and if they do have an ACGO, consider its possible use in emergency situations such as encountered by Seif and Olympio.1 An example of such a use appears incidentally in a recent report by Kummar et al.,2 who also experienced a large leak from the circle breathing system when the absorber canister of their GE Aisys Carestation was replaced during a craniotomy. In their case, they changed breathing system to a Bain coaxial circuit connected to the ACGO of the GE Aisys Carestation. This action excluded the leak in the circle system and enabled continued ventilation of the patient’s lungs.
منابع مشابه
Expiratory limb ventilation during unique failure of the anesthesia machine breathing circuit.
751 March 2013 T anesthesia machine is the most integral piece of equipment used by anesthesia providers. When semiclosed circle systems are used, unidirectional valves become integral components that direct carbon dioxide containing gas across the absorbent and along the inspiratory limb, mixing with fresh gas as it flows into the patient. Unfortunately, human error is known to be the most com...
متن کاملA Novel Method for Retrograde Ventilation Applied on the Expiratory Limb of Anesthesia Machines
Methods: At baseline 100% oxygen, 32 mmHg end-tidal carbon dioxide (EtCO2), and 1% end tidal isoflurane, retrograde SIMVD ventilation was initiated at the same minute ventilation with 100% oxygen. Changes in inspired oxygen (FiO2), isoflurane (FiIso), and EtCO2 were measured and then a second set of data was obtained after doubling the ventilation rate. After return to baseline, another data se...
متن کاملAnesthesia machine breathing tube holder
dotracheal tube and are composed of inspiratory and expiratory corrugated limbs. The two breathing tubes carry respiratory gases with volatile anesthetics to and from patients during general anesthesia. Although longer corrugated breathing tubes allow the anesthesia machine to be located farther from the patients, they are so long and flexible that they tend to hang down below the operating tab...
متن کاملAn experimental study on the impacts of inspiratory and expiratory muscles activities during mechanical ventilation in ARDS animal model
In spite of intensive investigations, the role of spontaneous breathing (SB) activity in ARDS has not been well defined yet and little has been known about the different contribution of inspiratory or expiratory muscles activities during mechanical ventilation in patients with ARDS. In present study, oleic acid-induced beagle dogs' ARDS models were employed and ventilated with the same level of...
متن کاملThe Modification and Performance of a Large Animal Anesthesia Machine (Tafonius®) in Order to Deliver Xenon to a Horse
INTRODUCTION Xenon, due to its interesting anesthetic properties, could improve the quality of anesthesia protocols in horses despite its high price. This study aimed to modify and test an anesthesia machine capable of delivering xenon to a horse. MATERIALS AND METHODS An equine anesthesia machine (Tafonius, Vetronic Services Ltd., UK) was modified by including a T-connector in the valve bloc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 119 4 شماره
صفحات -
تاریخ انتشار 2013