Mechanics of Stabbing: Biaxial Measurement of Knife Stab Penetration of Skin Simulant

نویسندگان

  • M. D. Gilchrist
  • S. Keenan
  • M. Curtis
  • M. Cassidy
  • G. Byrne
  • M. Destrade
چکیده

This paper describes the development and use of a biaxial measurement device to analyse the mechanics of knife stabbings. In medicolegal situations it is typical to describe the consequences of a stabbing incident in relative terms that are qualitative and descriptive without being numerically quantitative. Here, the mechanical variables involved in the possible range of knifetissue penetration events are considered so as to determine the necessary parameters that would need to be controlled in a measurement device. These include knife geometry, in-plane mechanical stress state of skin, angle and speed of knife penetration, and underlying fascia such as muscle or cartilage. Four commonly available household knives with different geometries were used: the blade tips in all cases were single-edged, double-sided and without serrations. Appropriate synthetic materials were used to simulate the response of skin, fat and cartilage, namely polyurethane, compliant foam and ballistic soap, respectively. The force and energy applied by the blade of the knife and the out of plane displacement of the skin were all used successfully to identify the occurrence of skin penetration. The skin tension is shown to have a direct effect on both the force and energy for knife penetration and the depth of out of plane displacement of the skin simulant prior to penetration: larger levels of in-plane tension in the skin are associated with lower penetration forces, energies and displacements. Less force and energy are also required to puncture the skin when the plane of the blade is parallel to a direction of greater skin tension than when perpendicular. This is consistent with the observed behaviour when cutting biological skin: less force is required to cut parallel to the Langer lines than perpendicularly and less force is required to cut when the skin is under a greater level of tension. Finally, and perhaps somewhat surprisingly, evidence is shown to suggest that the quality control processes used to manufacture knives fail to produce consistently uniform blade points in knives that are nominally identical. The consequences of this are that the penetration forces associated with nominally identical knives can vary by as much as 100%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring knife stab penetration into skin simulant using a novel biaxial tension device.

This paper describes the development and use of a biaxial measurement device to analyse the mechanics of knife stabbings. In medicolegal situations it is typical to describe the consequences of a stabbing incident in relative terms that are qualitative and descriptive without being numerically quantitative. Here, the mechanical variables involved in the possible range of knife-tissue penetratio...

متن کامل

An assessment of human performance in stabbing.

Stab-resistant body armour is now becoming a standard item of equipment for police officers in the United Kingdom. In the UK these are usually required to have a stab resistance as specified by the Police Scientific Development Branch KR42 standard [G. Parker, PSDB Stab Resistant Body Armour Test Procedure, Police Scientific Development Branch, Publication No 10/93, 1993]. There are several oth...

متن کامل

Toward a Predictive Assessment of Stab-Penetration Forces.

Collaborative research between the disciplines of forensic pathology and biomechanics was undertaken to investigate the hyperelastic properties of human skin, to determine the force required for sharp instrument penetration of skin, and to develop a finite element model, which reflects the mechanisms of sharp instrument penetration. These studies have led to the development of a "stab metric," ...

متن کامل

A very unusual case of attempted suicide

We would like to present a case report of a very unusual suicide attempt. A 48-year-old female patient tried to commit suicide by stabbing herself with a kitchen knife into her neck. Suicide by self-stabbing is uncommon, constituting only 1-3% of suicide attempts. Patients with self-inflicted stab wounds may have a higher incidence of surgical interventions based on the stab location. Surprisin...

متن کامل

The Second Look after Fights: Why Wounds Might Not Only Be Superficial

Introduction. We present a case of intraosseous foreign body penetration due to knife attack and its emergency service management. Case. Seventeen-year-old patient was admitted to the emergency department with a knife cut over the right knee. In the local wound exploration during the extension position of the knee, deep tissue penetration was not observed. Therefore, the patient was discharged ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008