Near-infrared spectroscopy: exposing the dark (venous) side of the circulation.

نویسندگان

  • John P Scott
  • George M Hoffman
چکیده

The safety of anesthesia has improved greatly in the past three decades. Standard perioperative monitoring, including pulse oximetry, has practically eliminated unrecognized arterial hypoxia as a cause for perioperative injury. However, most anesthesia-related cardiac arrests in children are now cardiovascular in origin, and standard monitoring is unable to detect many circulatory abnormalities. Near-infrared spectroscopy provides noninvasive continuous access to the venous side of regional circulations that can approximate organ-specific and global measures to facilitate the detection of circulatory abnormalities and drive goal-directed interventions to reduce end-organ ischemic injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent advances in bedside microcirculation assessment in critically ill patients

Parameters related to macrocirculation, such as the mean arterial pressure, central venous pressure, cardiac output, mixed venous saturation and central oxygen saturation, are commonly used in the hemodynamic assessment of critically ill patients. However, several studies have shown that there is a dissociation between these parameters and the state of microcirculation in this group of patients...

متن کامل

Plethysmographic validation of near infrared spectroscopic monitoring of cerebral blood volume.

The validation of measurement of cerebral blood volume (CBV) and cerebral blood flow (CBF) using near infrared spectroscopy (NIRS) against jugular venous occlusion plethysmography is described. Repeated measurements in six infants were made using both techniques simultaneously. A close relationship between the two measurements of change in CBV was obtained in five infants. There was also a clos...

متن کامل

Determination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares

The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...

متن کامل

Correlation of intraoperative renal near infrared spectroscopy with the development of acute kidney injury in adult patients undergoing cardiac surgery using cardiopulmonary bypass

Introduction: The present study aimed to correlate renal oximetry near-infrared spectroscopy (NIRS) values with conventional non-invasive biomarkers for the early detection of acute kidney injury (AKI) in adult patients undergoing cardiac surgery using cardiopulmonary bypass (CPB). Accordingly, renal NIRS can be employed as a trending device for the prevention of AKI developmen...

متن کامل

Potential of Near-Infrared Reflectance Spectroscopy (NIRS) to Predict Nutrient Composition of Bromus tomentellus

Determination of forage quality of available species is one of the fundamentalfactors for the management of rangelands. Near-Infrared Reflectance Spectroscopy (NIRS)was used to analysis the Nitrogen (N), Acid Detergent Fiber (ADF), Dry MatterDigestibility (DMD) and Metabolizable Energy (ME) content of three phenological stages(vegetative, flowering and seeding) of Bromus tomentellus samples in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Paediatric anaesthesia

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2014