Chemical Shift Imaging of the lungs with hyperpolarized Xe-129: Results from a rabbit model of stereotactic lung radiosurgery with and without a radioprotector

نویسندگان

  • J. Mata
  • K. Sheng
  • P. Read
  • K. Ruppert
  • K. Hagspiel
  • T. Altes
  • W. Tobias
  • G. Cates
  • J. Brookeman
چکیده

control group (radiation only). A & B: CT scans with radiation treatment planning superimposed. Area in red received full radiation dose (3x11Gy). All animals received radiation in same location. C & D: CT scans at 8 weeks post radiation. While lung in C has homogeneous tissue density, the lung in D shows an area of hypodensity that correlates with the irradiated area (oval and arrow). E & F: ce-MRA at 8 weeks post radiation. At the same location as in the CT scan (D), the ce-MRA (F), shows evidence of low pulmonary perfusion (arrow). G & H: He-3 ventilation images at 8 weeks post radiation. Both animals present normal and homogeneous ventilation throughout both lungs. I & J: Normalized hp Xe-129 CSI maps. While the animal from the radioprotector group (I) shows a uniform distribution of the hp Xe-129 dissolved in the lung tissue (small elevation in the left lung upper lobe from pericardial fat), the animal from the control group (J) shows an elevation of the hp Xe-129 dissolved in the lung tissue due to a ventilation-perfusion mismatch caused by the radiation (arrow). Note the good correlation between the elevated area in J and the perfusion defect in F. Chemical Shift Imaging of the lungs with hyperpolarized Xe-129: Results from a rabbit model of stereotactic lung radiosurgery with and without a radioprotector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans

BACKGROUND One of the central physiological functions of the lungs is to transfer inhaled gases from the alveoli to pulmonary capillary blood. However, current measures of alveolar gas uptake provide only global information and thus lack the sensitivity and specificity needed to account for regional variations in gas exchange. METHODS AND PRINCIPAL FINDINGS Here we exploit the solubility, hig...

متن کامل

RF instrumentation for same‐breath triple nuclear lung MR imaging of 1H and hyperpolarized 3He and 129Xe at 1.5T

PURPOSE The hyperpolarized gases (3)He and (129)Xe have distinct properties and provide unique and complementary functional information from the lungs. A triple-nuclear, same-breath imaging examination of the lungs with (1)H, (3)He, and (129)Xe can therefore provide exclusive functional information from the gas images. In addition, the (1)H images provide complementary co-registered structural ...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

129Xe chemical shift in human blood and pulmonary blood oxygenation measurement in humans using hyperpolarized 129Xe NMR

PURPOSE To evaluate the dependency of the 129 Xe-red blood cell (RBC) chemical shift on blood oxygenation, and to use this relation for noninvasive measurement of pulmonary blood oxygenation in vivo with hyperpolarized 129 Xe NMR. METHODS Hyperpolarized 129 Xe was equilibrated with blood samples of varying oxygenation in vitro, and NMR was performed at 1.5 T and 3 T. Dynamic in vivo NMR durin...

متن کامل

3D Hyperpolarized (129)Xe MRI of mouse lung at low xenon concentration using a continuous flow-type hyperpolarizing system: feasibility for quantitative measurement of regional ventilation.

PURPOSE We investigated the feasibility of 3D hyperpolarized (HP) (129)Xe magnetic resonance (MR) imaging at an extremely low concentration of HP (129)Xe supplied from a continuous flow-type hyperpolarizing (CF-HP) system and established a standard procedure for measuring regional lung ventilation of small animals, such as the mouse, as a baseline for further studies. MATERIALS AND METHODS We...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008