The Accuracy of Tower' Maps to Display Curvature Data in Corneal Topography Systems

نویسنده

  • Cynthia Roberts
چکیده

Results. For the spherical surface, both curvature-based paraxial power approximations were uniform over the entire surface because curvature is constant. However, the corneal refractive power increased from center to periphery, demonstrating the known phenomenon of spherical aberration. For the ellipsoids, which have been shown to model the human cornea, curvature-based power approximations decreased from center to periphery because the curvature flattens peripherally. However, refractive power increased from center to periphery. The limits of the central paraxial region for these surfaces was shown to be approximately 2 mm in diameter for the paraxial power approximation used by videokeratographic devices to measure 8 mm in diameter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The accuracy of 'power' maps to display curvature data in corneal topography systems.

PURPOSE To quantify the error introduced by videokeratographic corneal topography devices in using a paraxial formula to calculate power over the entire corneal surface, including areas removed from the central paraxial region where the formula is known to be invalid. METHODS Corneal refractive power and two paraxial power approximations were computed as a function of distance from the apex f...

متن کامل

بررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه

 ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...

متن کامل

بررسی اصلاح قوز قرنیه با استفاده از قطعات ‏حلقوی داخل قرنیه‌ای فرارا

  Background and Objective: Evaluation of the results, safety, and stability of ferrara intracorneal ring segment (FICRS) implantation for Keratoconus correction (age range was 24.39±8.32 years).   Materials and Methods: In this clinical trial study, 64 eyes of 57 patients with keratoconus and clear cornea that had FICRS implantation were studied. Uncorrected visual acuity (UCVA), best-spectacl...

متن کامل

Comparison of Topographic Technologies in Anterior Surface Mapping of Keratoconus using Two Display Algorithms and Six Corneal Topography Devices

Purpose: To evaluate anterior surface topographic technologies and display algorithms in mapping keratoconus. Materials and methods: A total of 27 eyes of 17 subjects clinically diagnosed with keratoconus were imaged on six topographers: EyeSys, Alcon EyeMap, Keratron, TMS-1, Orbscan and PAR corneal topography system. Axial distance (AD) and instantaneous radius of curvature (IROC) algorithms w...

متن کامل

Landforms identification using neural network-self organizing map and SRTM data

During an 11 days mission in February 2000 the Shuttle Radar Topography Mission (SRTM) collected data over 80% of the Earth's land surface, for all areas between 60 degrees N and 56 degrees S latitude. Since SRTM data became available, many studies utilized them for application in topography and morphometric landscape analysis. Exploiting SRTM data for recognition and extraction of topographic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005