In vitro study of r-hirudin permeability through membranes of different haemodialysers.

نویسندگان

  • E Bucha
  • R Kreml
  • G Nowak
چکیده

BACKGROUND After introducing the specific thrombin inhibitor recombinant hirudin (r-hirudin) into clinical practice in cases of heparin-induced thrombocytopenia (HIT, type II) the possibility of its use as an anticoagulant during haemodialysis treatment in HIT II patients is being discussed more frequently. On the one hand, the efficient, safe and routine use of r-hirudin during haemodialyses, including the maintenance of a therapeutic blood level, presupposes that no r-hirudin will leave the circulation by passing through the dialyser membrane. On the other hand, it is important to have dialysers whose permeability to r-hirudin allows its efficient removal from the human body because, to date, no antidote is commercially available in cases of dangerously high blood concentrations of r-hirudin. METHODS An in vitro circulation model was used to study the r-hirudin permeability of some low- and high-flux dialysers. As r-hirudin-containing vehicles, both albumin-containing saline solution and bovine blood were circulated in the blood space of the system for 2 h. Transmembrane r-hirudin passage was tested by measuring r-hirudin concentration both in the blood and dialysate space fluids using the ecarin clotting time (ECT). RESULTS Low-flux dialysers with membranes made from polysulfone or regenerated cellulose proved to be almost impermeable to r-hirudin. In contrast, other low-flux membranes were partly permeable to r-hirudin (e.g. Hemophan) or even almost completely permeable (e.g. cellulose acetate). All high-flux dialysers tested were permeable to r-hirudin. CONCLUSIONS Only low-flux dialysers with polysulfone or regenerated cellulose membranes proved to be suitable for r-hirudin use in routine haemodialysis therapy. Other low-flux, and all high-flux, capillaries are permeable to r-hirudin and offer the possibility of lowering toxic r-hirudin concentrations after overdosing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term molecular efficacy and safety of imatinib in a patient with chronic myeloid leukaemia after renal transplantation.

in hemodialysis patients with heparin-induced thrombocytopenia. Am J Nephrol 2001; 21: 226–231 2. Fischer KG. Hirudin in renal insufficiency. Semin Thromb Hemost 2002; 28: 467–482 3. Greinacher A, Eichler P, Lubenow N, Kwasny H, Luz M. Heparin-induced thrombocytopenia with thromboembolic complications: meta-analysis of 2 prospective trials to assess the value of parenteral treatment with lepiru...

متن کامل

In vitro mitochondrial test to assess haemodialyser biocompatibility.

BACKGROUND This paper describes an in vitro mitochondrial test to assess the biocompatibility of haemodialysers. METHODS We tested on isolated liver mitochondria the effect of solutions obtained by an aqueous rinse of different haemodialysers (cuprophane, cellulose acetate, Hemophan, polyacrylonitrile, polymethylmethacrylate, polysulphone, polyamide). Moreover, to determine the penetration in...

متن کامل

An Investigation into the Effect of Various Penetration Enhancers on Percutaneous Absorption of Piroxicam

Achieving a desirable percutaneous absorption of drug molecule is a major concern in formulating dermatological products. The use of penetration enhancers could provide a successful mean for this purpose. The aim of this study was to evaluate the effect of incorporating a few common penetration enhancers (in different concentrations) into a 0.5% w/w piroxicam (model drug) gel formulation, on th...

متن کامل

An Investigation into the Effect of Various Penetration Enhancers on Percutaneous Absorption of Piroxicam

Achieving a desirable percutaneous absorption of drug molecule is a major concern in formulating dermatological products. The use of penetration enhancers could provide a successful mean for this purpose. The aim of this study was to evaluate the effect of incorporating a few common penetration enhancers (in different concentrations) into a 0.5% w/w piroxicam (model drug) gel formulation, on th...

متن کامل

Nano composite PEBAX®/PEG membranes: Effect of MWNT filler on CO2/CH4 separation

The performances of two-phase polymer-liquid PEBAX®/polyethylene glycol (PEG) and three-phase polymer-liquid-solid PEBAX®/PEG/MWNT thin film composite membranes for CO2 and CH4 permeation were studied. The effect of temperature and MWNT/PEBAX® ratio on single gas (CO2 and CH4) permeability was investigated. The permeat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 14 12  شماره 

صفحات  -

تاریخ انتشار 1999