Ultra Fast Electron Beam X-ray Computed Tomography for Two-phase Flow Measurement
نویسندگان
چکیده
Electron beam X-ray CT is a new technique for a fast measurement of multiphase flows with frame rates of 1000 images per second and more. It gives, in principle, quantitatively accurate images of the flow at high spatial resolution and it is non-intrusive since moderately radiation absorbing vessel walls can be penetrated by X-rays. However, on the road to a technical realisation of such a technique within a computed tomography system many problems have to be solved. As a first prototype for scientific flow measurement studies we devised and built a fast scanned electron beam X-ray tomography scanner. The scanner consists of an electron beam unit that can be operated at up to 150 kV acceleration voltage and up to 65 mA electron beam current, with the required electron optics for beam adjustment, beam focussing and beam deflection unit and a fast circular CZT detector comprising 240 elements of 1.5 mm x 1.5 mm x 1.5 mm active pixel area. X-ray radiation is produced on a circular water cooled tungsten target The CT system achieves up to 7000 frames per second with a spatial resolution of 1 millimetre. First two-phase flow experiments have been carried out on gas-water flows in bubble columns. On the basis of these data we developed image processing algorithms which enable to extract information on bubble shapes, bubble size distributions and interfacial area density distribution. Further, a vertical test section made of titanium alloy has been installed at the TOPFLOW facility and will be used in the future to study the evolution of two-phase gas-water pipe flow at high pressures and temperatures.
منابع مشابه
Ultra-fast x-ray tomography for multi-phase flow interface dynamic studies
Use of X-ray CT (Computer Tomography) system has been extended from medical fields to a variety of industrial applications [1, 2]. Among them is the visualization of multi-dimensional void distribution of two-phase flow in tubes. Mitsutake et al. [3] and Morooka et al. [4] used medical X-ray CT scanners modified for void fraction measurement within rod bundles. The results were comparable with ...
متن کاملECT and LS-SVM Based Void Fraction Measurement of Oil-Gas Two-Phase Flow
A method based on Electrical Capacitance Tomography (ECT) and an improved Least Squares Support Vector Machine (LS-SVM) is proposed for void fraction measurement of oil-gas two-phase flow. In the modeling stage, to solve the two problems in LS-SVM, pruning skills are employed to make LS-SVM sparse and robust; then the Real-Coded Genetic Algorithm is introduced to solve the difficult problem...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملDEPARTMENT of CARDIOVASCULAR SURGERY Quantification of Mitral Valve Regurgitation by Left Ventricular Volume and Flow Measurements Using Electron Beam Computed Tomography: Comparison with Magnetic Resonance Imaging
Method Forty-three patients, among them 33 with known mitral regurgitation, underwent electron beam CT and MR imaging. Total left ventricular stroke volume (TSV), antegrade stroke volume (ASV), and mitral regurgitation volume (MRV) and fraction (MRF) were determined and compared between the two modalities. Additionaly electron beam CT measurements were compared with the corresponding echocardio...
متن کاملPhase-contrast CT: Fundamental theorem and fast image reconstruction algorithms
Phase-contrast x-ray computed tomography (CT) is an emerging imaging technique that can be implemented at third generation synchrotron radiation sources or by using a microfocus x-ray tube. Promising experimental results have recently been obtained in material science and biological applications. At the same time, the lack of a mathematical theory comparable to that of conventional absorption-b...
متن کامل