Lethal Effects of Pulsed High-Voltage Discharge on Marine Plankton and Escherichia coli
نویسندگان
چکیده
Ballast seawater is considered globally as a major vector for invasions of non-indigenous organisms. Several technologies have been tested for their ability to remove organisms from ballast water. In the present study, we constructed a novel pulsed high-voltage discharge (PHVD) system that could operate in either high current mode with several hundred amperes or shockwave generating mode with relatively lower current in seawater. In laboratory-scale experiments, the PHVD system with shockwave-generating mode was found to be more effective in killing zooplankton (1.9to 4.0-fold) and phytoplankton (3.3-fold) than high current mode at discharge with 300–500 pulses at 7.1 kV. Further experiments were carried out at different voltages and pulse-numbers to examine effects of the shockwave-generating PHVD system on viabilities of one zooplankton larva, two phytoplankton species, and an indicator bacterium suspended in seawater in a static chamber. For zooplankton, live cells were not detected at discharge with 400 pulses at 13 kV. For phytoplankton, the initial live cells of a dinoflagellate was decreased by 77±0.5%, and the initial chl a concentration of a diatom was decreased by 76±6% at discharge with 700 pulses at 13 kV. For an indicator bacterium Escherichia coli, live cells were not detected at discharges with 200 or 700 pulses at 13 kV. Measurements of ATP content of organisms showed congruent results with those obtained by the above methods, suggesting it may be a rapid method for evaluating treatment efficiency. Though further scale-up studies are necessary, these results suggest that the PHVD system have a high potential for applying to ballast seawater treatment.
منابع مشابه
Prevalence, Antimicrobial Resistance, and Molecular Characterization of Escherichia coli Isolated from Food Contact Surfaces in Seafood Pre-Processing Plants (India)
Background: The survival of pathogens in biofilms poses a threat to food safety. The aim of this study was to determine prevalence, antimicrobial resistance, and molecular characterization of Escherichia coli strains. Methods: Swab samples (n=144) were collected from biofilm formed on food contact surfaces in seafood pre-processing plant in India. E. coli was isolated and identified using uid ...
متن کاملEffect of walnut tree root (Juglandaceae) on Escherichia coli resistant to antibiotics
The aim of this study was to evaluate the effect of walnut tree root (Juglandaceae) on Escherichia coli is resistant to various antibiotics. Walnut tree root extract was obtained using a rotary device. 20 cases of E. coli was obtained from urinary tract infections Zabul hospital and MIC and MBC were determined using dilution in the wells. The results of the study showed that the concentrations ...
متن کاملEffect of walnut tree root (Juglandaceae) on Escherichia coli resistant to antibiotics
The aim of this study was to evaluate the effect of walnut tree root (Juglandaceae) on Escherichia coli is resistant to various antibiotics. Walnut tree root extract was obtained using a rotary device. 20 cases of E. coli was obtained from urinary tract infections Zabul hospital and MIC and MBC were determined using dilution in the wells. The results of the study showed that the concentrations ...
متن کاملIsolation and Characterization of Two Lytic Bacteriophages Against Pseudomonas aeruginosa and Evaluation of Their Antibacterial Effects on Clinical Isolates of Staphylococcus aureus and Escherichia coli in The Northwest of Iran
Background and Objective: This study was carried out to isolate lytic bacteriophages against Pseudomonas aeruginosa and analyze their biological characteristics and antibacterial effects on other clinical isolates of bacteria. Methods: Isolating two lytic bacteriophages against two strains of P. aeruginosa was carried out using the double-layer agar method. After investigating the antibacteria...
متن کاملBench-Scale Disinfection of Bacteria and Viruses with Pulsed Arc Electrohydraulic Discharge
Pulsed arc electrohydraulic discharge (PAED) offers concurrent treatment of chemical and microbial target compounds in water by several mechanisms. Here, Escherichia coli, Bacillus subtilis spore, and MS2 bacteriophage inactivation by PAED were investigated using two bench-scale reactors (0.7 and 3 L). A plasma channel was created between a pair of iron electrodes set 0.5 mm apart in these reac...
متن کامل