Microscale extraction of perchlorate in drinking water with low level detection by electrospray-mass spectrometry.

نویسندگان

  • M L Magnuson
  • E T Urbansky
  • C A Kelty
چکیده

Improper treatment and disposal of perchlorate can be an environmental hazard in regions where solid rocket motors are used, tested, or stored. The solubility and mobility of perchlorate lends itself to ground water contamination, and some of these sources are used for drinking water. Perchlorate in drinking water has been determined at sub-mug l(-1) levels by extraction of the ion-pair formed between the perchlorate ion and a cationic surfactant with electrospray-mass spectrometry detection. Confidence in the selective quantification of the perchlorate ion is increased through both the use of the mass based detection as well as the selectivity of the ion pair. This study investigates several extraction solvents and experimental work-up procedures in order to achieve high sample throughput. The method detection limit for perchlorate based on 3.14sigma(n-1) of seven replicate injections was 300 ng l(-1) (parts-per-trillion) for methylene chloride extraction and 270 ng l(-1) for methyl isobutyl ketone extraction. Extraction with methylene chloride produces linear calibration curves, enabling standard addition to be used to quantify perchlorate in drinking water. Perchlorate determination of a contaminated water compared favorably with results determined by ion chromatography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of perchlorate at trace levels in drinking water by ion-pair extraction with electrospray ionization mass spectrometry.

Perchlorate has been added to the U.S. Environmental Protection Agency's Drinking Water Contaminant Candidate List (CCL). The present work describes the analysis of perchlorate in water by liquid-liquid extraction followed by flow injection electrospray mass spectrometry (ESI/MS). Cationic surfactants, mostly alkyltrimethyl-ammonium salts, are used to ion-pair aqueous perchlorate, forming extra...

متن کامل

Stripping analysis of nanomolar perchlorate in drinking water with a voltammetric ion-selective electrode based on thin-layer liquid membrane.

A highly sensitive analytical method is required for the assessment of nanomolar perchlorate contamination in drinking water as an emerging environmental problem. We developed the novel approach based on a voltammetric ion-selective electrode to enable the electrochemical detection of "redox-inactive" perchlorate at a nanomolar level without its electrolysis. The perchlorate-selective electrode...

متن کامل

Quantitation of Perchlorate Ion: Practices and Advances Applied to the Analysis of Common Matrices

In 1997, low-level perchlorate contamination (<50 ng mL–1 or parts per billion) was discovered in the western U.S. Since that time, it has been found in sites scattered around the nation. Although the Environmental Protection Agency has not established a regulation for perchlorate in drinking water, it has placed perchlorate on the contaminant candidate list (CCL) and the unregulated contaminan...

متن کامل

Analytical method for perchlorate in water by liquid chromatography-mass spectrometry using an ion exchange column.

A practical analytical method was developed for the routine analysis of perchlorate in environmental and drinking-water samples by liquid chromatography-electrospray ionization mass spectrometry (LC/ESI-MS) using an anion exchange column. By using (18)O-enriched perchlorate as an internal standard, the limits of quantification of perchlorate determined by tenfold of the signal-to-noise ratio an...

متن کامل

Quantitative analysis of perchlorate in extracts of whole fish homogenates by ion chromatography: comparison of suppressed conductivity detection and electrospray ionization mass spectrometry.

The perchlorate anion (ClO4-) is an anthropogenic contaminant of increasing concern in water supplies, and has been shown to disrupt thyroid activity. Most perchlorate analyses are currently carried out by ion chromatography (IC) with suppressed conductivity detection (SCD). While this procedure has been demonstrated to provide acceptable performance for analysis of water samples, the determina...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 52 2  شماره 

صفحات  -

تاریخ انتشار 2000