Hexamethylene diisocyanate (HDI) is used widely to manufacture polyurethanes for paints and coatings. It is an irritant and a chemical asthmagen. The U.S. Occupational Safety and Health Administration time-weighted average permissible exposure limit is 5 ppb and the ceiling limit is 20 ppb. We sought to develop a sensitive and specific immuno-bioassay to supplement workplace air monitoring and detect recent HDI exposure. For this, we produced rabbit antiserum to HDI-adducted keyhole limpet hemocyanin (HDI-KLH). The specificity of the antiserum was demonstrated by its reaction with a variety of HDI-conjugated proteins and the absence of reactions with conjugates of other diisocyanates, namely toluene diisocyanate and diphenyl methylene diisocyanate. Four immunoassays were developed and compared for their ability to detect decreasing quantities of HDI-adducted human serum albumin (HSA) containing 2 mol HDI adduct per mol HSA (HDI(2)-HSA) as determined by matrix-assisted laser desorption time-of-flight (MALDI-TOF) mass spectrometry. The sensitivities of some of the assays are within the range (0.82-45 nM) of current analytic methods. A Western analysis procedure has a sensitivity of 600 nM HDI adduct on HSA. ELISA inhibition assay, in which microtiter plates are coated with the HDI(2)-HSA antigen, has a sensitivity of 300 nM HDI adduct. An immunoblot assay has a sensitivity of 9 nM HDI adduct. The most sensitive bioassay (1.8 nM HDI adduct) is a three-antibody sandwich ELISA in which wells of microtiter plates are coated with the IgG fraction of the anti-HDI-KLH antisera. Compared with analytic methods for HDI biomonitoring, the immunoassays are faster and less costly and accommodate numerous samples simultaneously. The assays have the potential to affect industrial biomonitoring programs significantly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elimination kinetics of diisocyanates after specific inhalative challenges in humans: mass spectrometry analysis, as a basis for biomonitoring strategies

BACKGROUND Isocyanates are some of the leading occupational causes of respiratory disorders, predominantly asthma. Adequate exposure monitoring may recognize risk factors and help to prevent the onset or aggravation of these aliments. Though, the biomonitoring appears to be most suitable for exposure assessment, the sampling time is critical, however. In order to settle the optimal time point f...

متن کامل

بررسی تاثیر 1،6 هگزامتیلن دی ایزوسیا نات بر نتایج تست پیک فلومتری در کارگران کارگاه‌های رنگ کاری اتومبیل شهر اصفهان

Abstract Background & Aims: Hexamethylene diisocyanate is an aliphatic isocyanate and car painters are exposed to it. One of the most important disorders is occupational asthma. The aim of this study was to survey the effect of 1, 6 hexamethylene diisocyanate on the peak expiratory flow test to car painters in Isfahan. Materials & Methods: In this descriptive and a cross-sectional study the f...

متن کامل

Effect of 1,6-hexamethylene diisocyanate exposure on peak flowmetry in automobile paint shop workers in Iran.

The aim of this study was to investigate the effects of occupational exposure to 1,6-hexamethylene diisocyanate (HDI) on peak flowmetry in automobile body paint shop workers in Iran. We studied a population of 43 car painters exposed to HDI at their workplaces. Peak expiratory flow was tested for one working week, from the start to the end of each shift. Air was sampled and HDI analysed in para...

متن کامل

Characterization and comparative analysis of 2,4-toluene diisocyanate and 1,6-hexamethylene diisocyanate haptenated human serum albumin and hemoglobin.

Diisocyanates (dNCOs) are low molecular weight chemical sensitizers that react with autologous proteins to produce neoantigens. dNCO-haptenated proteins have been used as immunogens for generation of dNCO-specific antibodies and as antigens to screen for dNCO-specific antibodies in exposed individuals. Detection of dNCO-specific antibodies in exposed individuals for diagnosis of dNCO asthma has...

متن کامل

Isocyanate exposure in bathtub refinishing: à propos a case of occupational asthma.

Work-related asthma in a bathtub refinishing technician prompted measurements of isocyanate exposure in this operation. Very high levels of hexamethylene diisocyanate (HDI) oligomer, up to 8500 microg/m3 NCO, were found during top varnish spray-painting, whereas the levels of HDI monomer were substantially lower. The results suggest that only full-piece, self-contained respirators would suffice...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 109  شماره 

صفحات  -

تاریخ انتشار 2001