The nomogram of intracranial translucency in the first trimester in singletons.

نویسندگان

  • Rahime Nida Ergin
  • Murat Yayla
چکیده

OBJECTIVE Measurement of intracranial translucency (IT), which is a recent earlier recognizable sonographic marker, has been suggested for detection of spina bifida. In this prospective study we aimed to determine normative values of IT in the population of Turkish singleton pregnant women during the first trimester of pregnancy. MATERIAL AND METHODS Between January 2011 and July 2011, all consecutive singleton pregnant women were screened for intracranial translucency. Pregnancies were followed until birth. Pregnancies with any detected/suspicious anatomical or genetic fetal anomalies, biochemical abnormalities, increased nuchal translucency measurements, pregnancies of artificial reproduction techniques and anomaly detected at birth were set to be excluded from the data analyses. Mean±standard deviation, median and percentile values of intracranial translucency were calculated. Linear regression analyses were done between the length of intracranial translucency and gestational week and CRL. RESULTS Data analyses included 201 fetuses. Median maternal age was 31 years. Median CRL was 62 mm. Median gestational week was 12.57 weeks. Median IT value for the first trimester was 1.7 mm (range 1.00-2.40). Calculated formulae are; IT (mm)=[0.237×Gestational Week)]-1.27, R(2)=0.302; p<0.001 and IT (mm)=[0.020×CRL (mm)]+0.44, R(2)=0.381; p<0.001). IT measurements increased with increasing CRL and advancing gestational weeks. During follow up none of the fetuses was found to have any anatomical abnormality or anomaly. CONCLUSION This study presents normative values of intracranial translucency in the first trimester screening of normal singleton pregnancies of the Turkish population. In accordance with previous reports, intracranial translucency increases linearly with advancing CRL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Nuchal Translucency Measuremen in First Trimester Pregnancy

Background A significant number of pregnancies, particularly in women with previous histories of infertility, are associated with fetal abnormalities. Methods such as the nuchal translucency (NT) measurement enable us to identify more pregnancies with chromosomal abnormalities. MaterialsAndMethods This analytic cross-sectional study was performed in 446 pregnant women at 11-14 weeks gestation, ...

متن کامل

O-28: Detection of Fetal Major Structural Abnormalities with US in ART Patients during One Year

Background: The aims were to determine the diagnostic accuracy of ultrasound sonography in detecting major structural anomalies on all patients who conceived during a year of infertility treatment [assisted reproductive technology (ART) or non-ART treatments] at the Royan Institute, and to study the outcome of cases with nuchal translucency (NT) ≥ 95th centile in the first trimester of pregnanc...

متن کامل

P-226: Non-Invasive Prenatal Screening for Fetal Chromosomal Anomalies in South of Iran

Background: Prenatal diagnosis for Fetal Chromosomal anomalies currently relies on assessment of risk followed by a combination of biochemical and nuchal translucency. Trisomy 21 is the most common trisomy that is associated with intellectual disability. Pregnant women who receive a prenatal diagnosis of trisomy 21 currently have the option of continuing or terminating their pregnancy, but no f...

متن کامل

Intracranial translucency as a sonographic marker of open spina bifida at first trimester

Spina bifida is the one of the most common severe congenital abnormality of the central nervous system. Scalloping of the frontal bones called “the lemon sign” and caudal displacement of the cerebellum called “the banana sign” are known as cranial signs of open spina bifida on ultrasonography at the second trimester. Although these signs are useful methods in diagnosing of open spina bifida in ...

متن کامل

A comparison between maternal serum free beta-human chorionic gonadotrophin and pregnancy-associated plasma protein A levels in first-trimester twin and singleton pregnancies.

OBJECTIVES To determine the levels of first-trimester free beta-human chorionic gonadotrophin (free betahCG), pregnancy-associated plasma protein A (PAPP-A) and nuchal translucency (NT) in twin pregnancies. METHODS The study included 93 patients with twin pregnancy and 4,977 with singletons who underwent first-trimester testing using free betahCG, PAPP-A and NT at 10-13 weeks of gestational a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Turkish German Gynecological Association

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 2012