Mechanical considerations for the syndesmosis screw. A cadaver study.
نویسنده
چکیده
The purpose of this study was to examine the mechanical necessity of using a syndesmosis screw to supplement rigid internal fixation of the fibula and medial malleolus in the treatment of pronation-external rotation fractures. The legs of thirty embalmed and five fresh cadavera were dissected and mounted through the tibia to a frame so that multiple radiographs could be made with a constant relationship between the specimen and the x-ray apparatus. A standardized pronation-external rotation load was applied to the foot, and widening of the syndesmosis was studied on mortise radiographs that were made after each experimental step. On the basis of previous investigations, we developed a model for pronation-external rotation injuries that included disruption of the syndesmosis and interosseous membrane up to the level of the fibular fracture. Accordingly, multiple repaired fibular fractures could be simulated at several levels in the same specimen by incremental proximal division of the interosseous membrane. Specimens were separated into two groups. Group I consisted of thirteen specimens in which the deltoid ligament, syndesmosis, and interosseous membrane were serially sectioned in 1.5-centimeter increments. Group II (ten sections) was subjected to the same protocol, except that the deltoid ligament was kept intact until the final step. The five fresh specimens were sectioned in the same way as those in Group I. In Group I, since the simulated pronation-external rotation injury included a deltoid tear, rigid medial fixation was not possible; accordingly, there was rigid fibular fixation only.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Overtightening of the syndesmosis revisited and the effect of syndesmotic malreduction on ankle dorsiflexion.
BACKGROUND Ankle syndesmotic injuries are a significant source of morbidity and require anatomic reduction to optimize outcomes. Although a previous study concluded that maximal dorsiflexion during syndesmotic fixation was not required, methodologic weaknesses existed and several studies have demonstrated improved ankle dorsiflexion after removal of syndesmotic screws. The purposes of the curre...
متن کاملAnalysis of the Stress and Displacement Distribution of Inferior Tibiofibular Syndesmosis Injuries Repaired with Screw Fixation: A Finite Element Study
BACKGROUND Studies of syndesmosis injuries have concentrated on cadaver models. However, they are unable to obtain exact data regarding the stress and displacement distribution of various tissues, and it is difficult to compare models. We investigated the biomechanical effects of inferior tibiofibular syndesmosis injuries (ITSIs) and screw fixation on the ankle using the finite element (FE) met...
متن کاملThe use of calcium sulfate and calcium phosphate composite graft to augment screw purchase in osteoporotic ankles.
BACKGROUND Screws placed in the distal fibula may not have satisfactory purchase during internal fixation of an osteoporotic ankle fracture. Tibia-pro-fibula screws that extend from the fibula into the distal tibial metaphysis provide additional purchase. The purpose of this study was to investigate if purchase of these screws can be enhanced further by injecting calcium sulfate and calcium pho...
متن کاملA prospective randomised study comparing TightRope and syndesmotic screw fixation for accuracy and maintenance of syndesmotic reduction assessed with bilateral computed tomography.
BACKGROUND The accuracy and maintenance of syndesmosis reduction are essential when treating ankle fractures with accompanying syndesmosis injuries. The primary aim of this study was to compare syndesmosis screw and TightRope fixation in terms of accuracy and maintenance of syndesmosis reduction using bilateral computed tomography (CT). STUDY DESIGN Single centre, prospective randomised contr...
متن کاملOutcome after fixation of ankle fractures with an injury to the syndesmosis: the effect of the syndesmosis screw.
The purpose of this study was to compare the clinical and radiological outcome of patients with intact, broken and removed syndesmosis screws after Weber B or C ankle fracture with an associated injury to the syndesmosis. We hypothesised that there would be no difference. Of a possible 142 patients who fulfilled our inclusion criteria, 52 returned for clinical and radiological assessment at lea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 71 10 شماره
صفحات -
تاریخ انتشار 1989