Solar radiation and ambient temperature effects on the performances of a PV pumping system

نویسندگان

  • N. Hamrouni
  • M. Jraidi
  • A. Chérif
چکیده

This paper presents the influence of the solar radiation and ambient temperature variation on the performance of a stand alone photovoltaic pumping system which composed of a PV generator, DC-DC adaptor, DC-AC inverter and an immersed group motor-pump. Those performances such PV efficiency, inverter efficiency and flow rate are improved by a judicious control implanted on the converters. The maximal power point tracking (MPPT) control allows the extraction of the maximum output power delivered by the PV generator. However the inverter insures a pulse width modulation (PWM) control of the asynchronous motor and a sine wave form of output signals. We proceed to modelling the PV pumping system with power electronic converters allowing respectively optimal operating point tracking and power conversion under the appropriate command. From the obtained simulation results, under Matlab/Simulink environment, we will discuss how the ambient temperature and the solar radiation influence the performance of the PV plants. The experimental results of the PV pumping system installed in Tunisia (2.1 kWc) verify the validity of the model and the proposed controller. Résumé Cet article présente l’influence de l’irradiation solaire et de la variation de la température ambiante sur les performances d’un système de pompage photovoltaïque composé d’un générateur photovoltaïque, d’un adaptateur DC-DC, d’un onduleur DC-AC et d’un groupe moteur-pompe immergé. Ces performances telles que le rendement photovoltaïque, le rendement de l’onduleur et le taux du débit, sont améliorées par un système de contrôle judicieux implanté sur les convertisseurs. Le système de contrôleur du point de puissance maximal (MPPT) permet l’extraction du maximum de la puissance de sortie délivrée par le générateur photovoltaïque. Mais l’onduleur assure le contrôle de la modulation de largeur d’impulsions (PWM) du moteur asynchrone et de la forme de l’onde sinusoïdale des signaux de sortie. Nous procédons à la modélisation du système de pompage photovoltaïque avec des convertisseurs électroniques de puissance permettant de suivre respectivement le point optimal de fonctionnement et le rendement de conversion dans le cadre de la commande appropriée. A partir des résultats de simulation obtenus dans l’environnement Matlab/Simulink, nous allons discuter de l’influence de la température ambiante et du rayonnement solaire sur le fonctionnement des centrales photovoltaïques. Les résultats expérimentaux du système de pompage photovoltaïque installé en Tunisie (2,1 kWc) permettent de vérifier la validité du modèle et du contrôleur proposé.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation of Temperature Effects on Solar Photovoltaic Cells and Modules

The solar photovoltaic (PV) systems are facing serious problems due to unavoidable losses in their system, leads to more devation of output power from the input power level. This effect is known as a mismatch effect and is available in PV systems. Many losses are encountered in PV system and it is difficult to minimize such losses. In this paper, the influence of thermal effect on the solar PV ...

متن کامل

Optimal Operation of Standalone Pv Pumping System Based on an Induction Motor

In this paper, a PV array is used for water pumping purposes at remote or abandoned locations. Egypt is a developing country and largely depends on cultivation that won’t be possible without water availability. This paper presents the performances of a PV pumping system based on an induction motor under variable solar irradiations and ambient temperatures. The Maximum Power Point Tracker (MPPT)...

متن کامل

Study of the performance of a solar adsorption cooling system

This article presents a transient model of a solar adsorption cooling system. A computer program has been developed to simulate the operation of a two bed silica gel- water adsorption cooling system as well as flat plate collectors and the hot water storage tank. This program is then utilized to simulate the performance of a sample solar adsorption cooling system used for cooling a set of r...

متن کامل

A PSO-based Optimization of a fuzzy-based MPPT controller for a photovoltaic pumping system used for irrigation of greenhouses

The main asset of this paper is among the uses of fuzzy logic in the engineering sector and especially in the renewable energies as a large alternate of fossil energies, in this paper a PSO-based optimization is used to find the optimal scaling parameters, of a fuzzy logic-based MPPT controller, that maximize the efficiency of a photovoltaic pumping system. The tuning of input and output parame...

متن کامل

Experimental investigation of thermal and electrical performances of a nanofluid-cooled photovoltaic/thermal system equipped with a sheet-and-grooved serpentine tube collector

Introduction: In the present experimental investigation, the thermal and electrical performances of a photovoltaic/thermal system equipped with a sheet-and-grooved serpentine tube collector are investigated. The water-magnetite nanofluid is used as the heat transfer fluid. The effect of nanoparticle volume concentration (0-1%), nanofluid mass flow rate (10-40 kg/h) and groove pitch (0, 0.54 an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008