Efficient thermal infrared emitter with high radiant power
نویسنده
چکیده
Sensitive and selective gas measurements are crucial for a large variety of applications, e.g., explosion protection. Optical gas detection is usually based on the gas’ absorption of infrared radiation (IR). It is the leading technique in terms of accuracy, reliability, and economic efficiency. Since most gas measurements are made in the two wavelength ranges of (3 . . . 5) and (8 . . . 14) μm, a broadband IR source is necessary. In this paper, we report on a novel thermal IR emitter with high radiant power and a near-blackbody emission characteristic that can be modulated electrically. The layout of the IR source had been optimized by use of finite element analyses (FEA) in order to get an adequate electrical resistance as well as a homogeneous temperature distribution and a minimum deflection of the radiating element. Due to its excellent thermal isolation from the heat sink, the electrical power consumption is very low. Operating temperatures of up to 1400 K are possible, so that the fabricated IR source features a very high radiant power. Its application in gas analysis will improve the performance and efficiency of gas measurement systems.
منابع مشابه
Near-infrared–to–visible highly selective thermal emitters based on an intrinsic semiconductor
Control of the thermal emission spectra of emitters will result in improved energy utilization efficiency in a broad range of fields, including lighting, energy harvesting, and sensing. In particular, it is challenging to realize a highly selective thermal emitter in the near-infrared-to-visible range, in which unwanted thermal emission spectral components at longer wavelengths are significantl...
متن کاملImproved Infrared Imaging of Semiconductor Devices
Infrared thermal microscopy is a widely used tool for the thermal analysis of microelectronic circuits [1]. It is a noncontact measurement technique and utilizes naturally emitted infrared radiation from a sample. Commercial IR microscopes are readily available, offering a maximum spatial resolution of ~ 3 μm and a range of analysis options, including real time thermal mapping and thermal trans...
متن کاملDecoupling Intensity Radiated by the Emitter in Distance Estimation from Camera to IR Emitter
Various models using radiometric approach have been proposed to solve the problem of estimating the distance between a camera and an infrared emitter diode (IRED). They depend directly on the radiant intensity of the emitter, set by the IRED bias current. As is known, this current presents a drift with temperature, which will be transferred to the distance estimation method. This paper proposes...
متن کامل‘Squeezing’ near-field thermal emission for ultra-efficient high-power thermophotovoltaic conversion
We numerically demonstrate near-field planar ThermoPhotoVoltaic systems with very high efficiency and output power, at large vacuum gaps. Example performances include: at 1200 °K emitter temperature, output power density 2 W/cm(2) with ~47% efficiency at 300 nm vacuum gap; at 2100 °K, 24 W/cm(2) with ~57% efficiency at 200 nm gap; and, at 3000 °K, 115 W/cm(2) with ~61% efficiency at 140 nm gap....
متن کاملUltraviolet-nanoimprinted packaged metasurface thermal emitters for infrared CO2 sensing
Packaged dual-band metasurface thermal emitters integrated with a resistive membrane heater were manufactured by ultraviolet (UV) nanoimprint lithography followed by monolayer lift-off based on a soluble UV resist, which is mass-producible and cost-effective. The emitters were applied to infrared CO2 sensing. In this planar Au/Al2O3/Au metasurface emitter, orthogonal rectangular Au patches are ...
متن کامل