Prediction of small-for-gestational-age neonate by third-trimester fetal biometry and impact of ultrasound-delivery interval.

نویسندگان

  • Q Reboul
  • A Delabaere
  • Z C Luo
  • A-M Nuyt
  • Y Wu
  • C Chauleur
  • W Fraser
  • F Audibert
چکیده

OBJECTIVES To compare third-trimester ultrasound screening methods to predict small-for-gestational age (SGA), and to evaluate the impact of the ultrasound-delivery interval on screening performance. METHODS In this prospective study, data were collected from a multicenter singleton cohort study investigating the links between various exposures during pregnancy with birth outcome and later health in children. We included women, recruited in the first trimester, who had complete outcome data and had undergone third-trimester ultrasound examination. Demographic, clinical and biological variables were also collected from both parents. We compared prediction of delivery of a SGA neonate (birth weight < 10th percentile) by the following methods: abdominal circumference (AC) Z-score based on Hadlock curves (Hadlock AC), on INTERGROWTH-21st Project curves (Intergrowth AC) and on Salomon curves (Salomon AC); estimated fetal weight (EFW) Z-score based on Hadlock curves (Hadlock EFW) and on customized curves from Gardosi (Gardosi EFW); and fetal growth velocity based on change in AC between second and third trimesters (FGVAC). We also assessed the following ultrasound-delivery intervals: ≤ 4 weeks, ≤ 6 weeks and ≤ 10 weeks. RESULTS Third-trimester ultrasound was performed in 1805 patients with complete outcome data, of whom 158 (8.8%) delivered a SGA neonate. Ultrasound examination was at a median gestational age of 32 (interquartile range, 31-33) weeks. The ultrasound-delivery interval was ≤ 4 weeks in 17.2% of cases, ≤ 6 weeks in 48.1% of cases and ≤ 10 weeks in 97.3% of cases. Areas under the receiver-operating characteristics curve (AUC) were 0.772 for Salomon AC, 0.768 for Hadlock EFW, 0.766 for Hadlock AC, 0.765 for Intergrowth AC, 0.708 for Gardosi EFW and 0.674 for FGVAC (all P < 0.0001). The screening method with the highest AUC for an ultrasound-delivery interval ≤ 4 weeks was Salomon AC (AUC, 0.856), ≤ 6 weeks was Hadlock AC (AUC, 0.824) and ≤ 10 weeks was Salomon AC (AUC, 0.780). At a fixed 10% false-positive rate, the best detection rates were 60.0%, 54.1% and 42.1% for intervals ≤ 4, ≤ 6 and ≤ 10 weeks, respectively. CONCLUSION Third-trimester ultrasound measurements provide poor to moderate prediction of SGA. A shorter ultrasound-delivery interval provides better prediction than does a longer interval. Further studies are needed to test the effect of including maternal or biological characteristics in SGA screening. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of First Trimester Screening in the Prognostication of Small for Gestational Age

Background: Fetal growth restriction is defined as the failure of the fetus to achieve its full growth potential. The present study aimed to investigate the application of first trimester screening in the prediction of small for gestational age (SGA).Methods: This cohort study was conducted on the consecutive and unselected women with singleton pregnancies undergoing routine first-trimester exa...

متن کامل

Impact on obstetric outcome of third-trimester screening for small-for-gestational-age fetuses.

OBJECTIVES To evaluate the performance of screening for small-for-gestational-age (SGA) fetuses by ultrasound biometry at 30-35 weeks' gestation, and to determine the impact of screening on obstetric and neonatal outcomes. METHODS For this prospective cohort study, pregnant women were recruited from two French university maternity centers between 2003 and 2006. Performance measures of third-t...

متن کامل

Prediction of large-for-gestational-age neonates: screening by maternal factors and biomarkers in the three trimesters of pregnancy.

OBJECTIVE To develop a model based on maternal characteristics and medical history (maternal factors) for the prediction of delivery of large-for-gestational-age (LGA) neonates, and to examine the potential value of first-, second- and third-trimester fetal biometry and biomarkers in improving such a model. METHODS This was a screening study in 76 300, 54 999, 25 727 and 6181 singleton pregna...

متن کامل

Prediction of small-for-gestational-age neonates: screening by fetal biometry at 35-37 weeks.

OBJECTIVE To investigate the value of fetal biometry at 35-37 weeks' gestation in the prediction of delivery of small-for-gestational-age (SGA) neonates, in the absence of pre-eclampsia (PE). METHODS This was a screening study in singleton pregnancies at 35-37 weeks' gestation, comprising 278 that delivered SGA neonates with a birth weight < 5th percentile and 5237 cases unaffected by SGA, PE...

متن کامل

Prediction of small-for-gestational-age neonates: screening by biophysical and biochemical markers at 19-24 weeks.

OBJECTIVE To investigate the value of combined screening by maternal characteristics and medical history, fetal biometry and biophysical and biochemical markers at 19-24 weeks' gestation, for prediction of delivery of small-for-gestational-age (SGA) neonates, in the absence of pre-eclampsia (PE), and examine the potential value of such assessment in deciding whether the third-trimester scan sho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 2017