Top - Level Design and Preliminary Physical Analysis for the First Electron - Beam Micro - CT Scanner
نویسندگان
چکیده
A state of the art X-ray micro-CT scanner takes about 20 seconds to acquire a full dataset, which is too slow to capture the rapidly beating heart of small animals. We have been working to develop the first electron-beam micro-CT (EBMCT) prototype for cardiac imaging of the mice and rats. In this paper, we describe the background on electron-beam CT (EBCT) and emphasize the needs for EBMCT. Then, we present a top-level design and a preliminary physical analysis for the first EBMCT scanner. The proposed EBMCT prototype would allow 0.03-0.01s temporal resolution (35-70 half-scans per second) with 0.2mm spatial resolution and 5% contrast resolution. Finally, we discuss a few related issues to further highlight that this project is not only important for basic biomedical research but also feasible technically.
منابع مشابه
Optimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition
Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to optimize imaging parameters in micro-computed tomography (CT) scanner based on the signal-to-noise ratio (SNR) of urinary stones for the analysis of stone composition. <stro...
متن کاملDesign, analysis and simulation for development of the first clinical micro-CT scanner.
In this article, we propose to develop the first clinical micro-CT (CMCT) system for human temporal bone imaging in vivo. This CMCT system consists of medical CT and micro-CT scanners either as separate components or in a combination, a cross-modality registration mechanism such as a facial surface scanner, and associated software. This system integrates the strengths of state-of-the-art medica...
متن کاملFree Vibration Analysis of SVC Systems Based on Reddy-Levinson Model Using DQM
In this study, the free vibration analysis of smart vibration control (SVC) systems based on Reddy – Levinson model and modified strain gradient theory is developed. This system consist of a micro beam at middle and two magneto-electro-elastic (MEE) composite micro beams at top and bottom which connected by enclosing elastic medium and simulated by Winkler and Pasternak foundation. The effects ...
متن کاملValidation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملMechanical Behavior of a FGM Capacitive Micro-Beam Subjected to a Heat Source
This paper presents mechanical behavior of a functionally graded (FG) cantilever micro-beam subjected to a nonlinear electrostatic pressure and thermal moment considering effects of material length scale parameters. Material properties through the beam thickness direction are graded. The top surface of the micro-beam is made of pure metal and the bottom surface from a mixture of metal and ceram...
متن کامل