An improved delivery system for bladder irrigation
نویسندگان
چکیده
INTRODUCTION Occasionally, urologists may see patients requiring temporary bladder irrigation at hospitals without stocks of specialist irrigation apparatus. One option is to transfer the patient to a urology ward, but often there are outstanding medical issues that require continued specialist input. Here, we describe an improved system for delivering temporary bladder irrigation by utilizing readily available components and the novel modification of a sphygmomanometer blub. This option is good for bladder irrigation in patients with moderate or severe gross hematuria due to various causes. MATERIALS AND METHODS In this prospective study from March 2007 to April 2009, we used our new system in eligible cases. In this system, an irrigant bag with 1 L of normal saline was suspended 80 cm above the indwelled 3-way Foley catheter, and its drainage tube was inserted into the irrigant port of the catheter. To increase the flow rate of the irrigant system, we inserted a traditional sphygmomanometer bulb at the top of the irrigant bag. This closed system was used for continuous bladder irrigation (CBI) in patients who underwent open prostatectomy, transurethral resection of the prostate (TURP), or transurethral resection of the bladder (TURB). This high-pressure system is also used for irrigation during cystourethroscopy, internal urethrotomy, and transurethral lithotripsy. Our 831 eligible cases were divided into two groups: group 1 were endourologic cases and group 2 were open prostatectomy, TURP, and TURB cases. The maximum and average flow rates were evaluated. The efficacy of our new system was compared prospectively with the previous traditional system used in 545 cases. RESULTS In group 1, we had clear vision at the time of endourologic procedures. The success rate of this system was 99.5%. In group 2, the incidence of clot retention decreased two fold in comparison to traditional gravity-dependent bladder flow system. These changes were statistically significant (P = 0.001). We did not observe any adverse effects such as bladder perforation due to our high-pressure, high-flow system. CONCLUSION A pressurized irrigant system has better visualization during endourologic procedures, and prevents clot formation after open prostatectomy, TURP, and TURB without any adverse effects.
منابع مشابه
معرفی یک مدل ریاضی جدید برای ارزیابی و بهینه سازی عملکرد کانالهای آبیاری
Poor performance of irrigation canals and its effect on decreasing of Agricultural water productivity require attention for their improvement. In this paper a new mathematical model is introduced which could present optimal operation considering downstream requirements of turnouts, canal inlet flow, actual constraints and real conditions of canal system. Four performance indicators of delivery ...
متن کاملمعرفی یک مدل ریاضی جدید برای ارزیابی و بهینه سازی عملکرد کانالهای آبیاری
Poor performance of irrigation canals and its effect on decreasing of Agricultural water productivity require attention for their improvement. In this paper a new mathematical model is introduced which could present optimal operation considering downstream requirements of turnouts, canal inlet flow, actual constraints and real conditions of canal system. Four performance indicators of delivery ...
متن کاملIntra-abdominal irrigation at cesarean delivery: a randomized controlled trial.
OBJECTIVE To determine whether avoiding intra-abdominal irrigation at cesarean delivery will decrease rates of intraoperative and postoperative gastrointestinal disturbance without increasing postoperative morbidity. METHODS This was a randomized controlled trial of patients undergoing cesarean delivery. Patients were randomized to irrigation after closure of the hysterotomy compared with no ...
متن کاملCurcumin improved liposomal mitomycin-induced cell toxicity in bladder cancer cell
Objective (s): This study aimed at investigation of preparation and stability study of Mitomycin and Mitomycin loaded nanoliposems and efficacy of the combination of Mitomycin -loaded nanoliposomes and Curcumin versus Mitomycin in suppressing HTB-9 and L929 cell lines, in vitro.Materials and Methods: An HPLC method was validated based on Q2 (R1) International Conference on Harmonization (ICH) g...
متن کاملThumb cellulitis attributable to group G streptococcus.
is considered endemic in hospitals and long-term care facilities, an ongoing debate exists about whether all identified cases of MRSA, particularly in asymptomatic individuals, should be treated. There is little disagreement, however, regarding the use of MRSA to treat symptomatic infections. Intermittent as well as continuous bladder irrigation utilizing various pharmacological agents has been...
متن کامل