Cavity ring-down spectroscopy of Doppler-broadened absorption line with sub-MHz absolute frequency accuracy.

نویسندگان

  • C-F Cheng
  • Y R Sun
  • H Pan
  • Y Lu
  • X-F Li
  • J Wang
  • A-W Liu
  • S-M Hu
چکیده

A continuous-wave cavity ring-down spectrometer has been built for precise determination of absolute frequencies of Doppler-broadened absorption lines. Using a thermo-stabilized Fabry-Pérot interferometer and Rb frequency references at the 780 nm and 795 nm, 0.1 - 0.6 MHz absolute frequency accuracy has been achieved in the 775-800 nm region. A water absorption line at 12579 cm(-1) is studied to test the performance of the spectrometer. The line position at zero-pressure limit is determined with an uncertainty of 0.3 MHz (relative accuracy of 0.8 × 10(-9)).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous wave cavity ring down spectroscopy measurements of velocity distribution functions of argon ions in a helicon plasma.

We report continuous wave cavity ring down spectroscopy (CW-CRDS) measurements of ion velocity distribution functions (VDFs) in low pressure argon helicon plasma (magnetic field strength of 600 G, T(e) ≈ 4 eV and n ≈ 5 × 10(11) cm(-3)). Laser induced fluorescence (LIF) is routinely used to measure VDFs of argon ions, argon neutrals, helium neutrals, and xenon ions in helicon sources. Here, we d...

متن کامل

Cavity ring-down spectroscopy for quantitative absorption measurements

We examine under what conditions cavity ring-down spectroscopy ~CRDS! can be used for quantitative diagnostics of molecular species. We show that CRDS is appropriate for diagnostics of species whose absorption features are wider than the spacing between longitudinal modes of the optical cavity. For these species, the absorption coefficient can be measured by CRDS without a knowledge of the puls...

متن کامل

Ultrasensitive, self-calibrated cavity ring-down spectrometer for quantitative trace gas analysis.

A cavity ring-down spectrometer is built for trace gas detection using telecom distributed feedback (DFB) diode lasers. The longitudinal modes of the ring-down cavity are used as frequency markers without active-locking either the laser or the high-finesse cavity. A control scheme is applied to scan the DFB laser frequency, matching the cavity modes one by one in sequence and resulting in a cor...

متن کامل

High-precision and high-accuracy rovibrational spectroscopy of molecular ions.

We present a versatile new instrument capable of measuring rovibrational transition frequencies of molecular ions with sub-MHz accuracy and precision. A liquid-nitrogen cooled positive column discharge cell, which can produce large column densities of a wide variety of molecular ions, is probed with sub-Doppler spectroscopy enabled by a high-power optical parametric oscillator locked to a moder...

متن کامل

CAVITY RING-DOWN SPECTROSCOPY OF O2-O2 COLLISIONAL INDUCED ABSORPTION M. SNEEP and W. UBACHS

Absolute cross sections (peak and band-integrated) for collision-induced absorption features in oxygen at 630, 577 and 477 nm are determined using the laser-based technique of cavity ring-down spectroscopy. A wavelength-dependent background, Rayleigh scattering extinction and oxygen-monomer absorption are unraveled from the collision-induced features and its quadratic pressure dependence is dem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 20 9  شماره 

صفحات  -

تاریخ انتشار 2012