Gelatinase and the Gates-gilman-cowgill Method of Pepsin Estimation

نویسنده

  • Elizabeth R. B. Smith
چکیده

The Gates photographic film method for pepsin estimation as developed by Gilman and Cowgill measures an activity corresponding to that determined by the hemoglobin method of Anson and Mirsky rather than that resulting from the use of the gelatin viscosity technique. Therefore, the presence of gelatinase is not a source of great error in the gelatin film procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The gastric secretion of pepsin in man TABLE III

The control of gastric pepsin secretion continues to excite controversy. The diversity in the results obtained by different investigators may be due, at least in part, to the varying techniques employed to estimate pepsin activity. Thus, edestin (Polland and Bloomfield, 1929), gelatin (Gilman and Cowgill, 1930), egg albumen (Vineberg and Babkin, 1931), beef haemoglobin (Anson and Mirsky, 1932),...

متن کامل

The gastric secretion of pepsin in man TABLE

The control of gastric pepsin secretion continues to excite controversy. The diversity in the results obtained by different investigators may be due, at least in part, to the varying techniques employed to estimate pepsin activity. Thus, edestin (Polland and Bloomfield, 1929), gelatin (Gilman and Cowgill, 1930), egg albumen (Vineberg and Babkin, 1931), beef haemoglobin (Anson and Mirsky, 1932),...

متن کامل

Studies of Gastric Pepsin. Ii. Secretion of Pepsin in Cases of Duodenal Ulcer and Pseudo-ulcer.

Few articles on concentration of pepsin in the gastric juice of patients with disease of the stomach and duodenum are to be found in recent literature, and the results reported by different observers are not always in accord. We shall consider here only the concentration of pepsin in the gastric juice of persons suffering with the syndrome of peptic ulcer. Wilcox (5), in 1908, reported that the...

متن کامل

A Design Methodology for Reliable MRF-Based Logic Gates

Probabilistic-based methods have been used for designing noise tolerant circuits recently. In these methods, however, there is not any reliability mechanism that is essential for nanometer digital VLSI circuits. In this paper, we propose a novel method for designing reliable probabilistic-based logic gates. The advantage of the proposed method in comparison with previous probabilistic-based met...

متن کامل

The Determination of Peptic Activity: an Exam- Ination and Application of the Gates Method of Proteolytic Enzyme Titration

Despit.e the numerous methods for the determination of proteolytic enzymes, there are few, if any, which incorporate all the advantages of accuracy, simplicity, and brevity, and which require only a small sample for a determination. In 1927 Gates (1) published a preliminary report of a proteolytic enzyme titration possessing these desirable features, and demonstrated his method at the 1928 meet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of General Physiology

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2003