Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice

نویسندگان

  • Marjolein J C Schot
  • Sanne van Delft
  • Antoinette M J Kooijman-Buiting
  • Niek J de Wit
  • Rogier M Hopstaken
چکیده

OBJECTIVE Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. SETTING All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. PRIMARY AND SECONDARY OUTCOME MEASURES Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. RESULTS The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. CONCLUSIONS The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of antibiogram test results of patients suspected of urinary tract infection with two methods, fast and classic

Background: Urinary tract infections are among the most common diseases in different communities and occur in all age groups. Failure to diagnose the disease correctly and promptly can cause complications such as damage to the urinary tract and kidney parenchyma, increased blood pressure, uremia. Also, in pregnant female patients It may lead to premature birth and even abortion. Therefore, corr...

متن کامل

Analytical performance, agreement and user-friendliness of five C-reactive protein point-of-care tests.

BACKGROUND Point-of-care (POC) C-reactive protein (CRP) testing is increasingly used in primary care to assist general practitioners (GPs) in the diagnostic workup for various complaints. The present study compares analytical performance, agreement and user-friendliness of five of these POC CRP tests. METHODS The following five POC CRP tests were evaluated: Afinion and NycoCard Reader II (bot...

متن کامل

Prevalence and Microbiological Profile of Catheter Associated Urinary Tract Infections: A Case Study in Secondary Care Hospital

Background and Objectives: Healthcare-associated infections is a major health care concern posing potentially serious negative impact on patient safety and outcome. In this paper, we report this microbiological profile and the prevalence of Catheter Associated Urinary Tract Infections (CAUTIs). Methods: This was a prospective observational study for...

متن کامل

Evaluating the diagnostic value of nitrite test in comparison with U/S results in patients with urinary tract infection symptoms: A cross-sectional study

Objective: The purpose of this study is to evaluate the diagnostic value of nitrite test in comparison with urine culture (U/C) results in patients with Urinary tract infection (UTI) symptoms.Methods: This cross-sectional study was performed on 203 patients with UTI symptoms. Middle urine sample was taken into sterile plastic containers, and simultaneously the urine sample and the nitrite...

متن کامل

An Overview of Candiduria

Candida microorganisms frequently exist as saprophytes on the external genitalia or urethra, however, yeast in measurable quantities are found in <1% of clean voided urine specimens. The overall frequency of Candida infections in hospitals has increased by 200% to 300% in the last decade, such that in a general hospital 5% of urine cultures may yield Candida species, and in tertiary-care center...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015