Synthetic ECG generation and Bayesian filtering using a Gaussian wave-based dynamical model.
نویسندگان
چکیده
In this paper, we describe a Gaussian wave-based state space to model the temporal dynamics of electrocardiogram (ECG) signals. It is shown that this model may be effectively used for generating synthetic ECGs as well as separate characteristic waves (CWs) such as the atrial and ventricular complexes. The model uses separate state variables for each CW, i.e. P, QRS and T, and hence is capable of generating individual synthetic CWs as well as realistic ECG signals. The model is therefore useful for generating arrhythmias. Simulations of sinus bradycardia, sinus tachycardia, ventricular flutter, atrial fibrillation and ventricular tachycardia are presented. In addition, discrete versions of the equations are presented for a model-based Bayesian framework for denoising. This framework, together with an extended Kalman filter and extended Kalman smoother, was used for denoising the ECG for both normal rhythms and arrhythmias. For evaluating the denoising performance, the signal-to-noise ratio (SNR) improvement of the filter outputs and clinical parameter stability were studied. The results demonstrate superiority over a wide range of input SNRs, achieving a maximum 12.7 dB improvement. Results indicate that preventing clinically relevant distortion of the ECG is sensitive to the number of model parameters. Models are presented which do not exhibit such distortions. The approach presented in this paper may therefore serve as an effective framework for synthetic ECG generation and model-based filtering of noisy ECG recordings.
منابع مشابه
Speech Enhancement Using Gaussian Mixture Models, Explicit Bayesian Estimation and Wiener Filtering
Gaussian Mixture Models (GMMs) of power spectral densities of speech and noise are used with explicit Bayesian estimations in Wiener filtering of noisy speech. No assumption is made on the nature or stationarity of the noise. No voice activity detection (VAD) or any other means is employed to estimate the input SNR. The GMM mean vectors are used to form sets of over-determined system of equatio...
متن کاملBayesian Analysis of Censored Spatial Data Based on a Non-Gaussian Model
Abstract: In this paper, we suggest using a skew Gaussian-log Gaussian model for the analysis of spatial censored data from a Bayesian point of view. This approach furnishes an extension of the skew log Gaussian model to accommodate to both skewness and heavy tails and also censored data. All of the characteristics mentioned are three pervasive features of spatial data. We utilize data augme...
متن کاملBayesian denoising framework of phonocardiogram based on a new dynamical model
In this paper, we introduce a model-based Bayesian denoising framework for phonocardiogram (PCG) signals. The denoising framework is ounded on a new dynamical model for PCG, which is capable of generating realistic synthetic PCG signals. The introduced dynamical model is ased on PCG morphology and is inspired by electrocardiogram (ECG) dynamical model proposed by McSharry et al. and can represe...
متن کاملECG denoising and fiducial point extraction using an extended Kalman filtering framework with linear and nonlinear phase observations.
In this paper we propose an efficient method for denoising and extracting fiducial point (FP) of ECG signals. The method is based on a nonlinear dynamic model which uses Gaussian functions to model ECG waveforms. For estimating the model parameters, we use an extended Kalman filter (EKF). In this framework called EKF25, all the parameters of Gaussian functions as well as the ECG waveforms (P-wa...
متن کاملApplication of Dynamic Time Warping on Kalman Filtering Framework for Abnormal ECG Filtering
Existing nonlinear Bayesian filtering frameworks serve as an effective tool for the model-based filtering of noisy ECG recordings. However, since these methods are based on linear phase assumption, for some heart defects where abnormal waves only appear in certain cycles of the ECG, they are unable to simultaneously filter the normal and abnormal ECG segments. In this paper, a new method based ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physiological measurement
دوره 31 10 شماره
صفحات -
تاریخ انتشار 2010