Measuring moderate-intensity walking in older adults using the ActiGraph accelerometer
نویسندگان
چکیده
BACKGROUND Accelerometry is the method of choice for objectively assessing physical activity in older adults. Many studies have used an accelerometer count cut point corresponding to 3 metabolic equivalents (METs) derived in young adults during treadmill walking and running with a resting metabolic rate (RMR) assumed at 3.5 mL · kg-1 · min-1 (corresponding to 1 MET). RMR is lower in older adults; therefore, their 3 MET level occurs at a lower absolute energy expenditure making the cut point derived from young adults inappropriate for this population. The few studies determining older adult specific moderate-to-vigorous intensity physical activity (MVPA) cut points had methodological limitations, such as not measuring RMR and using treadmill walking. METHODS This study determined a MVPA hip-worn accelerometer cut point for older adults using measured RMR and overground walking. Following determination of RMR, 45 older adults (mean age 70.2 ± 7 years, range 60-87.6 years) undertook an outdoor, overground walking protocol with accelerometer count and energy expenditure determined at five walking speeds. RESULTS Mean RMR was 2.8 ± 0.6 mL · kg-1 · min-1. The MVPA cut points (95% CI) determined using linear mixed models were: vertical axis 1013 (734, 1292) counts · min-1; vector magnitude 1924 (1657, 2192) counts · min-1; and walking speed 2.5 (2.2, 2.8) km · hr-1. High levels of inter-individual variability in cut points were found. CONCLUSIONS These MVPA accelerometer and speed cut points for walking, the most popular physical activity in older adults, were lower than those for younger adults. Using cut points determined in younger adults for older adult population studies is likely to underestimate time spent engaged in MVPA. In addition, prescription of walking speed based on the adult cut point is likely to result in older adults working at a higher intensity than intended.
منابع مشابه
How many days of monitoring predict physical activity and sedentary behaviour in older adults?
BACKGROUND The number of days of pedometer or accelerometer data needed to reliably assess physical activity (PA) is important for research that examines the relationship with health. While this important research has been completed in young to middle-aged adults, data is lacking in older adults. Further, data determining the number of days of self-reports PA data is also void. The purpose of t...
متن کاملAssessment of physical activity in older Belgian adults: validity and reliability of an adapted interview version of the long International Physical Activity Questionnaire (IPAQ-L)
BACKGROUND Adequate monitoring of older adults' physical activity (PA) is essential to develop effective health promotion programs. The present study examined criterion validity and test-retest reliability of the long International Physical Activity Questionnaire (IPAQ-L), adapted for Belgian, community-dwelling older adults (65 y and older). METHODS Participants (n = 434) completed the last ...
متن کاملValidity of treadmill- and track-based individual calibration methods for estimating free-living walking speed and VO2 using the Actigraph accelerometer
BACKGROUND For many patients clinical prescription of walking will be beneficial to health and accelerometers can be used to monitor their walking intensity, frequency and duration over many days. Walking intensity should include establishment of individual specific accelerometer count, walking speed and energy expenditure (VO2) relationships and this can be achieved using a walking protocol on...
متن کاملComparison of older and newer generations of ActiGraph accelerometers with the normal filter and the low frequency extension
BACKGROUND Many studies used the older ActiGraph (7164) for physical activity measurement, but this model has been replaced with newer ones (e.g., GT3X+). The assumption that new generation models are more accurate has been questioned, especially for measuring lower intensity levels. The low-frequency extension (LFE) increases the low-intensity sensitivity of newer models, but its comparability...
متن کاملConcurrent validity of the PAM accelerometer relative to the MTI Actigraph using oxygen consumption as a reference.
The purpose of this study was to examine the concurrent validity of the Personal Activity Monitor (PAM) accelerometer relative to the Actigraph accelerometer using oxygen consumption as a reference, and to assess the test-retest reliability of the PAM. Thirty-two fit, normal weight adults (aged 21-54) performed two activities, treadmill walking and stair walking, while wearing the PAM, the Acti...
متن کامل