Variability of the hill of vision and its significance in automated perimetry.

نویسندگان

  • N A Jacobs
  • I H Patterson
چکیده

It has been assumed that the retinal threshold sensitivity profile is a standard which decreases predictably with age. On this basis the significance of relative scotomata is decided on certain types of perimeter. The hill of vision was measured in 128 healthy eyes on the Dicon 2000 autoperimeter. We found a large variation between individuals, with no relationship to age. The relevance of the findings to automated perimetry are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability in short-wavelength automated perimetry among peri- or postmenopausal women: a dependence on phyto-oestrogen consumption?

PURPOSE To determine whether the hill of vision for Short-Wavelength Automated Perimetry (SWAP) is shallower for women who consume phyto-oestrogen-rich foods than for women who do not. METHODS Visual field data were compared for two groups of healthy amenorrhoeic women 48-69 years-old with normal vision and not using hormone replacement: (1) 24 subjects who reported consuming soy and/or flax ...

متن کامل

Topography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.

BACKGROUND Traquair described the topography of visual field sensitivity as a "hill" or "island" of vision. Achromatic automated perimetry (AAP) demonstrates this shape of the visual field in photopic conditions. Techniques claimed to target the magnocellular pathway (frequency doubling perimetry, FDP) and those using a stimulus targeting the koniocellular pathway (short wavelength (or blue on ...

متن کامل

Modeling the sensitivity to variability relationship in perimetry

PURPOSE Studies in glaucoma patients show that standard automated perimetry results increase in variability as sensitivity decreases. However, the reasons for this change are unclear. This study presents the principle of Divergent Dysfunction as a possible explanation for this change in variability, and incorporates it into a model that can be used to simulate perimetry. METHODS A computer pr...

متن کامل

Evaluation of stimulus velocity in automated kinetic perimetry in young healthy participants

This prospective study aimed to evaluate the stimulus velocity for automated kinetic perimetry based on the test duration, the kinetic sensitivity, and the variability of the kinetic sensitivity in 31 eyes of 31 young healthy participants. Automated kinetic perimetry was performed using an Octopus 900 perimeter with Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. The participants underwent test...

متن کامل

Investigating the effects of glaucomatous (POAG) damage on the mVEP parameters

Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 69 11  شماره 

صفحات  -

تاریخ انتشار 1985