Polydimethylsiloxane: a new contrast material for localization of occult breast lesions
نویسندگان
چکیده
BACKGROUND The radioguided localization of occult breast lesions (ROLL) technique often utilizes iodinated radiographic contrast to assure that the local injection of (99m)Tc-MAA corresponds to the location of the lesion under investigation. However, for this application, this contrast has several shortcomings. The objective of this study was to evaluate the safety, effectiveness and technical feasibility of the use of polydimethylsiloxane (PDMS) as radiological contrast and tissue marker in ROLL. MATERIALS AND METHODS.: The safety assessment was performed by the acute toxicity study in Wistar rats (n = 50). The radiological analysis of breast tissue (n = 32) from patients undergoing reductive mammoplasty was used to verify the effectiveness of PDMS as contrast media. The technical feasibility was evaluated through the scintigraphic and histologic analysis. RESULTS We found no toxic effects of PDMS for this use during the observational period. It has been demonstrated in human breast tissue that the average diameter of the tissue marked by PDMS was lower than when marked by the contrast medium (p <0.001). PDMS did not interfere with the scintigraphic uptake (p = 0.528) and there was no injury in histological processing of samples. CONCLUSIONS This study demonstrated not only the superiority of PDMS as radiological contrast in relation to the iodinated contrast, but also the technical feasibility for the same applicability in the ROLL.
منابع مشابه
Assessment of Ultrasound / Radio-guided Occult Lesion Localization in Non-palpable Breast Lesions
Objective(s): Controversy exists about the localization of non-palpable breast lesions. In many countries, the gold standard for the diagnosis of these lesions is needle localization due to its accuracy. This study sought to compare the ultrasoundand radio-guided occult lesion localization (ROLL) as a simple method with the conventional procedures in terms of their diagnostic power. Methods: Th...
متن کاملResults of the radioguided surgeries among the patients with pathological nipple discharge
Introduction: Nipple discharge is the third most common complaint of the breast diseases following the breast mass and the breast pain. The majority of the lesions causing pathological nipple discharge (PND) consist of non-palpable breast lesions (NPBLs). When non-operative diagnostic tools are inadequate to distinguish the diagnosis, the pathological duct should be removed to ...
متن کاملMagnetic resonance imaging-guided occult breast lesion localization and simultaneous sentinel lymph node mapping
BACKGROUND Radio-guided occult lesion localization is a valid technique for the diagnosis of suspicious non-palpable lesions. Here we determine the feasibility of pre-operative localization of occult suspect non-palpable breast lesions using radio-guided occult lesion localization, as well as for identifying the sentinel lymph node. METHODS This is a descriptive study of data collected retros...
متن کاملRadio-guided occult lesion localization for nonpalpable suspicious breast lesions: A novel technique
Background: Breast screening programs and increased self-awareness has led to increased identification of early breast cancers. Up to 25% of mammographicaly identified lesions are nonpalpable, which require a precise technique to localize and excise completely. Radio-guided occult lesion localization (ROLL) is a technique, which uses hand held gamma probe to accurately localize and completely e...
متن کاملMRI-guided Needle Localization for Breast Lesions Occult in Mammograms and Ultrasound
To evaluate the diagnostic eff icacy of breast magnetic resonance imaging (MRI)-guided needle localization and surgical biopsy for suspicious breast lesions occult on physical breast examination, mammography and second-look ultrasound. Twelve patients (age range, 29-68 years; mean 44.9±9.24 years) received breast MR-guided needle localization and surgical biopsy for the suspicious lesions detec...
متن کامل