Impact of a new conduction defect after transcatheter aortic valve implantation on left ventricular function.
نویسندگان
چکیده
OBJECTIVES This study sought to evaluate the impact of new conduction defects after transcatheter aortic valve implantation (TAVI) on the evolution of left ventricular (LV) function during 1-year follow-up. BACKGROUND New left bundle branch block (LBBB) or need for permanent pacing due to atrioventricular (AV) block are frequent after TAVI. METHODS A total of 90 consecutive patients treated with TAVI and who had 12-month echocardiographic follow-up were included in the study. In 39 patients, a new conduction defect (new LBBB or need for permanent pacemaker activity.) persisted 1 month after TAVI. In 51 patients, no persistent new conduction defect was observed. Two-dimensional echocardiography using parasternal short-axis, apical 4-chamber, and apical 2-chamber views was performed before TAVI and at 1-year follow-up to determine LV volumes and ejection fraction based on Simpson's rule. Speckle-tracking echocardiography was applied using standard LV short-axis images to assess the effect of new conduction defects on time-to-peak radial strain of different LV segments as a parameter of LV dyssynchrony. RESULTS New conduction defects resulted in marked heterogeneity in time-to-peak strain between the 6 analyzed short-axis segments. During 1-year follow-up after TAVI, there was a significant increase in left ventricular ejection fraction (LVEF) in patients without new LBBB (53 ± 11% pre TAVI to 59 ± 10% at follow-up; p < 0.001), whereas there was no change in LVEF in patients with a new conduction defect (52 ± 11% pre TAVI to 51 ± 12% at follow-up, p = 0.740). Change in LV end-systolic volume was also significantly different between patient groups (-1.0 ± 14.2 vs. -11.2 ± 15.7 ml, p = 0.042). New conduction defect and LVEF at baseline were independent predictors of reduced LVEF at 12-month follow-up after TAVI. CONCLUSIONS LVEF improves after TAVI for treatment of severe aortic stenosis in patients without new conduction defects. In patients with a new conduction defect after TAVI, there is no improvement in LVEF at follow-up.
منابع مشابه
Permanent pacemaker implantation after transcatheter aortic valve implantation: impact on late clinical outcomes and left ventricular function.
BACKGROUND Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS A total of 1556 consecutive patients without prior PPI undergoing transcathete...
متن کاملLeft ventricular remodelling and prosthetic valve function after transcatheter aortic valve implantation: A serial cardiac magnetic resonance imaging study
Background Transcatheter aortic valve implantation (TAVI) has become a common procedure for high-risk patients with severe aortic stenosis. Aortic regurgitation (AR) is commonly seen after TAVI, but little is known about how it evolves over time. Similarly, the impact of TAVI on left ventricular (LV) function, LV volumes and mass is not well defined.Paravalvular aortic regurgitation (AR) is fre...
متن کاملPlatypnea-Orthodeoxia Syndrome after Transcatheter Aortic Valve Implantation
Progressive dyspnea and hypoxaemia in the subacute phase after transcatheter aortic valve implantation (TAVI) are uncommon and warrant immediate assessment of valve and prosthesis leaflet function to exclude thrombosis, as well as investigation for other causes related to the procedure, such as left ventricular dysfunction, pulmonary embolism, and respiratory sepsis. In this case, we report the...
متن کاملIncreased Pacemaker Implantation Rate After New-Generation Balloon-Expandable SAPIEN 3 Valve: Who Was to Blame, the Valve or the Doctor?
SEE PAGE 805 T he occurrence of conduction disturbances and the need for permanent pacemaker implantation remain a significant issue associated with transcatheter aortic valve replacement (TAVR) (1). Indeed, the contiguity of the conduction system to the aortic annulus (landing zone of transcatheter valve prostheses) makes this procedure likely to develop this complication (2). To date, several...
متن کاملTemporal changes in left ventricular function and paravalvular aortic regurgitation after transcatheter aortic valve implantation: a cardiac magnetic resonance imaging study
Background Transcatheter aortic valve implantation (TAVI) has been established as a therapeutic alternative in patients with severe aortic stenosis at high risk for surgery. Paravalvular aortic regurgitation (AR) is frequent after TAVI. Yet, little data is available about temporal changes of AR and the impact of TAVI on left ventricular (LV) function and dimensions. We used cardiac MRI to evalu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular interventions
دوره 5 12 شماره
صفحات -
تاریخ انتشار 2012