The use of thermistor probes to measure energy distribution in ultrasound fields.
نویسندگان
چکیده
The use of small thermistors coated with absorbing material for the measurement of ultrasound fields is discussed. Equilibrium temperature rise gives a rough measure of intensity, but is affected by convective cooling due to streaming. The initial rate of temperature rise provides an accurate parameter for use in assessing energy density in all types of ultrasound field. Measurements made in standing wave fields show that the thermistor response is related to the pressure component of the sound wave, and is determined by absorption throughout the coating material.
منابع مشابه
Role of ultrasound probes in transmission of hospital infections
Background: The ultrasonography probes are cleaned by absorbent soft, dry cloth. This question arose whether linear and convex ultrasound probes coupling with gel could perform as a means for nosocomial infections transmission, and which method is economical and more efficient for cleaning the probes. This study was conducted to answer these questions. Methods: One hundred – ninety two patients...
متن کاملWashing Insulators by Ultrasound Sonication Method to Remove Hard Sediments Caused by Dust and Aerosols
Correct and timely maintenance of power lines and substations has an important impact on the operation and optimization of the production cycle and distribution of electricity. In this way, proper and timely maintenance and repair of these lines can reduce losses, sudden defects, and thus reduce and optimize consumption. One of the most important components of transmission and distribution netw...
متن کاملInvestigating the Effects of Cut-Out Shield on High-Energy Electron Fields Using MAGIC Normoxic Polymer Gel
Introduction The use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (PDD) curves. These changes and electron beam dose distribution in the form of three-dimensional (3D) can be measured by gel dosimeters. Materials and Methods Dosimetry was performed with and without a square shield (6×6 cm2 field). The energies were 4, 9, and 16 MeV and phantom w...
متن کاملQuantum dots of CdS synthesized by micro-emulsion under ultrasound: size distribution and growth kinetics
Quantum dots of CdS with hexagonal phase were prepared at relatively low temperature (60 oC) and short time by micro-emulsion (O/W) under ultrasound. This study was focused on the particle size distribution and the growth kinetics. The particle size distribution obtained from the optical absorption edge. It was relatively symmetrical with sonication time. In addition, an agreement was observed ...
متن کاملA melting-point-of gallium apparatus for thermometer calibration.
We have investigated the equilibrium melting point of gallium as a temperature fixed-point at which to calibrate small thermistor thermometers, such as those used to measure temperature in enzyme reaction analysis and other temperature-dependent biological assays. We have determined that the melting temperature of "6N" (99.999% pure) gallium is 29.770 +/- 0.002 degrees C, and that the constant-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasonics
دوره 18 3 شماره
صفحات -
تاریخ انتشار 1980