Quantitative angiographic comparison of elastic recoil after coronary excimer laser-assisted balloon angioplasty and balloon angioplasty alone.

نویسندگان

  • S Strikwerda
  • E M van Swijndregt
  • R Melkert
  • P W Serruys
چکیده

OBJECTIVES Coronary lumen changes during and after excimer laser-assisted balloon angioplasty were measured by quantitative coronary angiography, and the results were compared with the effects of balloon angioplasty alone. BACKGROUND Reduction of atherosclerotic tissue mass by laser ablation in the treatment of coronary artery disease may be more effective in enlarging the lumen than balloon angioplasty alone. METHODS A series of 57 consecutive coronary lesions successfully treated by xenon chloride excimer laser-assisted balloon angioplasty were individually matched with 57 coronary artery lesions successfully treated by balloon angioplasty alone. The following variables were measured by quantitative coronary analysis: 1) ablation by laser, 2) stretch by balloon dilation, 3) elastic recoil, and 4) acute gain. RESULTS Matching by stenosis location, reference diameter and minimal lumen diameter resulted in two comparable groups of 57 lesions with identical baseline stenosis characteristics. Minimal lumen diameter before excimer laser-assisted balloon angioplasty and balloon angioplasty alone were (mean +/- SD) 0.73 +/- 0.44 and 0.74 +/- 0.43 mm, respectively. Laser ablation significantly improved minimal lumen diameter by 0.56 +/- 0.44 mm before adjunctive balloon dilation. In both treatment groups, similar-sized balloon catheters (2.59 +/- 0.35 and 2.56 +/- 0.40 mm, respectively) were used. After laser-assisted balloon angioplasty, elastic recoil was 0.84 +/- 0.30 mm (32% of balloon size), which was identical to that after balloon angioplasty alone, namely, 0.82 +/- 0.32 mm (32%). Consequently, both interventions resulted in similar acute gains of 1.02 +/- 0.52 and 1.00 +/- 0.56 mm, respectively. Minimal lumen diameter after intervention was equal in both groups: 1.75 +/- 0.35 and 1.75 +/- 0.34 mm, respectively. The statistical power of this study in which a 25% difference in elastic recoil (0.2 mm) between groups was considered clinically important was 95%. CONCLUSIONS In matched groups of successfully treated coronary lesions, xenon chloride excimer laser ablation did not reduce immediate elastic recoil after adjunctive balloon dilation or improve the final angiographic outcome compared with balloon angioplasty alone using similar-sized balloon catheters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate and late outcome of excimer laser and balloon coronary angioplasty: a quantitative angiographic comparison based on matched lesions.

OBJECTIVES This study sought to compare acute lumen changes and late lumen narrowing during and after excimer laser-assisted balloon angioplasty, measured by quantitative coronary angiography, with the immediate and long-term outcome of balloon angioplasty alone. BACKGROUND Although excimer laser coronary angioplasty is used as an adjunct or alternative to balloon angioplasty, limited compara...

متن کامل

Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease.

BACKGROUND Excimer laser coronary angioplasty is reported to give excellent procedural results for treatment of complex coronary lesions, but this method has not been compared with balloon angioplasty in a randomised trial. METHODS Patients (n = 308) with stable angina and coronary lesions longer than 10 mm on visual assessment were included. 151 patients (158 lesions) were assigned randomly ...

متن کامل

Angiographic Risk Factors of Luminal Narrowing After Coronary Balloon Angioplasty Using Balloon Measurements to Reflect Stretch and Elastic Recoil at the Dilatation Site

Because many ongoing clinical restenosis prevention trials are using quantitative angiography to assess whether a drug is capable of reducing the amount of intimal hyperplasia, quantitative angiographic risk factors for angiographic luminal narrowing after balloon angioplasty were determined, including stretch and elastic recoil at the dilatation site. Quantitative analysis was performed on 666...

متن کامل

Clinical and angiographic outcome in patients with in-stent restenosis and repeat target lesion revascularisation in small coronary arteries.

OBJECTIVE To evaluate the clinical and angiographic outcome in patients with in-stent restenosis in small coronary arteries and repeat target lesion revascularisation. DESIGN Patients with in-stent restenosis in coronary arteries < or = 2.85 mm were eligible for the study and underwent target lesion revascularisation. Clinical and angiographic variables were assessed during a six month follow...

متن کامل

Laser angioplasty of restenosed coronary stents: results of a multicenter surveillance trial. The Laser Angioplasty of Restenosed Stents (LARS) Investigators.

OBJECTIVES This study evaluated safety and efficacy of excimer laser angioplasty for treatment of restenosed or occluded coronary stents. BACKGROUND Balloon angioplasty of in-stent restenosis is limited by a high recurrence rate. Debulking by laser angioplasty is a novel concept to treat in-stent restenosis. METHODS A total of 440 patients with restenoses or occlusions in 527 stents were en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 1995