Falsely high refractometric readings for the specific gravity of pleural fluid.
نویسنده
چکیده
For 128 pleural fluids, the relationship between the protein content and the reading for the specific gravity obtained from a refractometer calibrated for urinary specific gravity was analyzed. The refractometer gave falsely high levels for the specific gravity of the pleural fluid. A reading for 1.019 (rather than 1.016) corresponded to a concentration of protein of 3.0 gm/100 ml, and each deviation of 0.005 (rather than 0.003) coresponded to a concentration of 1 gm/100 ml; however, determinations of the concentration of protein in the pleural fluid directly from the refractometer's scale for protein (calibrated for serum) was rapid and accurate. Calculation of the protein content of the pleural fluid from the reading for specific gravity on the refractometer is erroneous and sometimes misleading.
منابع مشابه
Diagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid
Background: Accumulation of pleural and peritoneal fluid is seen in some diseases. In order to diagnose the disease and start the treatment, one of the most important actions will be to differentiate between exudates and transudates. The objective of this study was to determine the diagnostic value of measuring the specific gravity of the fluid through...
متن کاملDiagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid
BACKGROUND Accumulation of pleural and peritoneal fluid is seen in some diseases. In order to diagnose the disease and start the treatment, one of the most important actions will be to differentiate between exudates and transudates. The objective of this study was to determine the diagnostic value of measuring the specific gravity of the fluid through refractometer and strip in differentiation ...
متن کامل18F-FDG PET/CT in pleural epithelioid hemangioendothelioma
Pleural epithelioid hemangioendothelioma (EHE) is a rare malignancy of vascular-endothelial origin with non-specific symptoms and an unpredictable outcome. Diagnosis of this condition by imaging modalities is challenging, and no standard therapeutic approaches have been established in this regard. In this paper, we described the case of a patient with a low-grade fever, coughing and chest pain ...
متن کاملA novel bedside technique for differentiation of exudative from transudative pleural effusion
Abstract Background: At present, differentiation between exudative and transudative pleural effusion is based solely on laboratory measures and is time-consuming. Asimple bedside method would be of great help to differentiate between these two types of effusions. We present a new method for this purpose assessed in 46 patients. Methods: Standard laboratory tests and our method were tested...
متن کاملRefractometric determination of total solids and water of serum and urine.
Refractometric analysis of total solids in serum and urine is simple, accurate, and rapid. Adolph (1) demonstrated the high coefficient of correlation between refractive index and total solids of dog plasma and subsequently employed refractometry as an index of the total solids of human serum (2). Blohm (3), using a dipping refractometer, showed for human urine that the reading given by that fl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 76 3 شماره
صفحات -
تاریخ انتشار 1979