Exposure to Microbial Aerosols from Activated Sludge Treatment

نویسنده

  • H. F. Young
چکیده

Viab le pathogens are generally present at every stage of wastewater treatment. Thus a potential airborne infectious pathway due to microbial aerosols exists~ particularly at activated sludge treatment plants. In this study the concentration of sewage-borne indicator bacteria and viruses in effZuent aerosols was determined and the exposure to such aerosols by treatment plant workers was estimated. Initial aerosol collection with fog-gage screen collectors yielded erratic results due especially to lack of control over sampled air volume and slit openings too large for effective collection. Standard Andersen and glass impinger collectors were used throughout the field study. Areas downwind of aeration basins yielded as much as 1 657 CFU/m 3 total bacteria and 1.8 PFU/m 3 coliphage. These aerosols were mostly 2.1 to 3.3 j.JTn droplet nuclei with a high potential for inhalation and bronchial retention. The inhalation of microbial aerosols by Wahiawa treatment plant workers was estimated to be between 48 to 94 total bacteria/person/day above background levels. The inhaled total coliform level may average 8 to 27 CFU/ person/day. This usually short duration and sometimes intense exposure could not be implicated directly to cause adverse health effects. Correlations of statistical tabulations of sick-leave illness with degree of exposure were not significant at the 0.01 or the 0.05 level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Comparison of Two Modifications of Activated Sludge for Treatment of Furfural-Containing Wastewater

 A case study is presented in which two modifications of activated sludge treatment of complex chemical wastewater are experimentally compared: a combination of common activated sludge with powdered activated carbon treatment (PACT), and bioaugmentation of activated sludge treatment (BAST). Industrial wastewater of Pars Oil Refinery that was passed through an oil recovery stage was used to inve...

متن کامل

Performance Evaluation of the Extended Aeration Activated Sludge System in the Removal of Physicochemical and Microbial Parameters of Municipal Wastewater: A Case Study of Nowshahr Wastewater Treatment Plant

Introduction: Extended aeration activated sludge system has a lower sludge production than other activated sludge processes. Due to its high hydraulic retention time (HRT), the tolerance of this process is higher than the shocks caused by increased organic loading rate. The main objective of this study is to evaluate the performance of the aeration system in removing physicochemical and mi...

متن کامل

Coupled Anaerobic Baffled Reactor (ABR)/Activated Sludge Treatment of Synthetic Wastewater with High Concentration of Sulfate and COD

A synthetic wastewater with high concentration of sulfate and COD was treated in anaerobic baffled reactor (ABR) coupled with an activated sludge. The work was accomplished in two phases. In the first phase, the concentration of sulfate was kept constant at 500mg/l, but COD concentration was increased from (3000mg/l to 6000mg/l), consequently, COD and sulfate removal in ABR reached to 80% and 9...

متن کامل

Prevalence of antibiotic resistant genes in selected activated sludge processes in Isfahan Province, Iran

Wastewater treatment plants are one of the main sources of dissemination of antibiotic resistance genes (ARGs) into the environment. The present study was conducted to determine the prevalence and removal of ARGs in different wastewater treatment processes. A total of 36 samples from raw and final effluent of different activated sludge processes were collected and analyzed. Molecular analysis w...

متن کامل

Effect of an activated sludge wastewater treatment plant on ambient air densities of aerosols containing bacteria and viruses.

Bacteria- and virus-containing aerosols were studied during the late summer and fall seasons in a midwestern suburb of the United States before and during the start-up and operation of an unenclosed activated sludge wastewater treatment plant. The study showed that the air in this suburban area contained low-level densities of indicator microorganisms. After the plant began operating, the densi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008