Factors affecting oxygen delivery with bi-level positive airway pressure.

نویسندگان

  • Andrew R Schwartz
  • Robert M Kacmarek
  • Dean R Hess
چکیده

INTRODUCTION Portable pressure ventilators, or bi-level ventilators, do not typically have an oxygen control, and thus supplemental oxygen is usually administered by adding it into the mask or the circuit. We conducted this study to test the hypothesis that delivered oxygen concentration using this configuration is affected by the choice of leak port, oxygen injection site, and ventilator settings. METHODS A lung model simulating spontaneous breathing was connected to the head of a manikin. An oronasal mask was attached to the manikin. A single-limb circuit was attached to the mask and a bi-level ventilator. Three leak ports were compared: leak in the mask, plateau exhalation valve with mask leak port occluded, and leak port in the circuit with mask leak port occluded. Bi-level positive airway pressure (BiPAP) settings of 10/5, 15/5, 20/5, 15/10, 20/10, and 25/10 cm H(2)O were used at respiratory rates of 15 and 25 breaths/min. Oxygen was added into the mask or into the circuit at the ventilator outlet, using flows of 5 and 10 L/min. Carbon dioxide was added into the lung model to produce an end-tidal P(CO(2)) of either 40 or 75 mm Hg. RESULTS Delivered oxygen concentration was not affected by respiratory rate (p = 0.22) or end-tidal P(CO(2)) (p = 0.74). The oxygen concentration was greater when oxygen was added into the circuit with the leak port in the mask (p < 0.001), whereas oxygen concentration was greater when oxygen was added into the mask with the leak port in circuit (p = 0.005). Oxygen concentration was significantly lower with the leak port in the mask (p < 0.001), with a higher inspiratory positive airway pressure (p < 0.001), and with a higher expiratory positive airway pressure (p < 0.001). The highest oxygen concentration was achieved with oxygen added to the mask, with the leak port in the circuit, and with the lowest settings of inspiratory (10 cm H(2)O) and expiratory (5 cm H(2)O) positive airway pressure. CONCLUSIONS Delivered oxygen concentration during BiPAP is a complex interaction between the leak port type, the site of oxygen injection, the ventilator settings, and the oxygen flow. Because of this, it is important to continuously measure arterial oxygen saturation via pulse oximetry with patients in acute respiratory failure who are receiving noninvasive ventilation from a bi-level ventilator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

Panel Discussion: Non-invasive Respiratory Support in NICU

Non-invasive respiratory support in the neonatal intensive care unit (NICU) is a mainstay to reduce complications of invasive mechanical ventilation. Nasal Continuous Positive Airway Pressure (CPAP) in infants is used for situations such as respiratory distress syndrome, apnea of prematurity, bronchomalacia with terminal airway collapse, and in other conditions that require positive pressure. T...

متن کامل

Treatment of sleep central apnea with non-invasive mechanical ventilation with 2 levels of positive pressure (bilevel) in a patient with myotonic dystrophy type 1

We are reporting a case of a 29 year-old female with diagnosis of myotonic dystrophy type 1 (Steinert's disease) with excessive daytime sleepiness, muscle fatigue, snoring, frequent arousals, non-restorative sleep, and witnessed apneas. Pulmonary function tests revealed a mild decrease of forced vital capacity. Nocturnal polysomnography showed an increase of apnea/hypopnea index (85.9 events/h)...

متن کامل

Effects of ventilator settings, nebulizer and exhalation port position on albuterol delivery during non-invasive ventilation: an in-vitro study

BACKGROUND Few studies have investigated the factors affecting aerosol delivery during non-invasive ventilation (NIV). Our aim was to investigate, using a bench-top model, the effect of different ventilator settings and positions of the exhalation port and nebulizer on the amount of albuterol delivered to a lung simulator. METHODS A lung model simulating spontaneous breathing was connected to...

متن کامل

Effectiveness of Nasal Intermittent Positive Pressure Ventilation versus Nasal Continuous Positive Airway Pressure in Preterm Infants after Less Invasive Surfactant Administration

Background Non-invasive ventilation is increased used in preterm infants. We aimed to compare the effectiveness of nasal intermittent positive pressure ventilation (nIPPV) versus nasal continuous positive airway pressure (nCPAP) in preterm infants with respiratory distress syndrome (RDS) after less invasive surfactant administration (LISA). Materials and Methods In this clinical trial, eighty ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 2004