Assessment of iothalamate plasma clearance: duration of study affects quality of GFR.

نویسندگان

  • Rajiv Agarwal
  • Jennifer E Bills
  • Paulos M Yigazu
  • Terri Abraham
  • Andinet B Gizaw
  • Robert P Light
  • Dagim M Bekele
  • Getachew G Tegegne
چکیده

BACKGROUND AND OBJECTIVES Measurement of GFR is important for the management of chronic kidney disease (CKD). Although bolus administration of radiocontrast agents is commonly used to measure GFR, the optimal duration of sampling to assess their plasma clearance is unknown. The purpose of this study was to evaluate whether the duration of plasma sampling influences precision and estimation of GFR. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS GFR was measured by sampling plasma 12 times over 5 h in 56 patients with CKD (mean age 64 yr, 98% men, 79% Caucasian, 34% diabetics, estimated GFR 31.8 +/- 14.2 ml/min/1.73 m(2)). In a subset of 12 patients we measured GFR by sampling plasma 17 times over 10 h. RESULTS Short sampling intervals considerably overestimated GFR measured using total plasma iothalamate clearance, especially in larger patients. In the higher estimated GFR group (>30 ml/min/1.73 m(2)), the 5-h GFR was 17% higher and 2-h GFR 54% higher compared with the 10-h GFR, which averaged 40.3 ml/min/1.73 m(2). In the lower estimated GFR group (<30 ml/min/1.73 m(2)), the 5-h GFR was 36% higher and 2-h GFR 126% higher compared with the 10-h GFR, which averaged 22.2 ml/min/1.73 m(2). Short sampling duration also reduced the precision of the estimated GFR from 1.67% for 10-h GFR, to 3.48% for 5-h GFR, and to 7.07% for 2-h GFR. CONCLUSIONS GFR measured over a longer duration with multiple plasma samples spanning the distribution and elimination phases may improve precision and provide a better measure of renal function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concordance Between Iothalamate and Iohexol Plasma Clearance.

To the Editor: Iohexol is regarded as an accurate filtration marker for measuring GFR. Recently, Soveri et al concluded that plasma clearance of iohexol could be considered a valid alternative to the gold standard, urinary clearance of inulin. Because inulin urinary clearance is cumbersome and costly, iohexol and iothalamate clearance have become popular in Europe and the United States, respect...

متن کامل

Determination of glomerular filtration rate using technetium-99m-DTPA with differing degrees of renal function.

UNLABELLED Glomerular filtration rate (GFR) is an important index of renal function. Twenty-four-hour creatinine clearance overestimates GFR in patients with poor renal function. Inulin and iothalamate clearances are accepted reference standards for determining GFR but are expensive and laborious. We have previously reported that GFRs obtained by measuring the disappearance of 99mTc-DTPA from u...

متن کامل

Measured GFR as a confirmatory test for estimated GFR.

Clinical assessment of kidney function is central to the practice of medicine. GFR is widely accepted as the best index of kidney function in health and disease, and accurate values are required for optimal decision making. Estimated GFR based on serum creatinine is now widely reported by clinical laboratories, and in most circumstances, estimated GFR is sufficient for clinical decision making....

متن کامل

Performance of the Chronic Kidney Disease Epidemiology Collaboration equation to estimate glomerular filtration rate in a longitudinal study of Autosomal Dominant Polycystic Kidney Disease

Glomerular filtration rate (GFR) can only be measured indirectly1. The gold standard is the renal clearance of inulin. Because it is cumbersome, alternative methods such as the renal clearance of iothalamate and plasma clearance of iohexol were developed. Other methods estimate GFR using equations based on endogenous filtration markers such as creatinine and cystatin C2. The Chronic Kidney Dise...

متن کامل

Hydrophilic pyrazine dyes as exogenous fluorescent tracer agents for real-time point-of-care measurement of glomerular filtration rate.

Various hydrophilic pyrazine-bis(carboxamides) derived from 3,5-diamino-pyrazine-2,5-dicarboxylic acid bearing neutral and anionic groups were prepared and evaluated for use as fluorescent glomerular filtration rate (GFR) tracer agents. Among these, the dianionic d-serine pyrazine derivatives 2d and 2j, and the neutral dihydroxypropyl 2h, exhibited favorable physicochemical and clearance proper...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical journal of the American Society of Nephrology : CJASN

دوره 4 1  شماره 

صفحات  -

تاریخ انتشار 2009