Robust nonlinear control of shunt active filters for harmonic current compensation

نویسندگان

  • Lorenzo Marconi
  • Fabio Ronchi
  • Andrea Tilli
چکیده

An advanced control strategy of shunt active filters (SAF) aiming to compensate for harmonic current in the electric supply grid is proposed. The SAF considered here is suitable for three-phase three-wire current harmonic compensation and is based on AC/DC three-phase boost converter topology. Robust control of the active-reactive current/power delivered by the SAF is designed exploiting the internal model principle. The stabilization of the DC-link voltage dynamics is addressed along with the fulfillment of the harmonics compensation objective. The two-time scale behavior of the SAF is exploited to apply the averaging theory in the control design. Experiments are provided to show the effectiveness of the proposed solution. 2006 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays

The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...

متن کامل

Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach

This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

متن کامل

Power System Harmonic Compensation Using Shunt Active Power Filter

This paper shows the method of improving the power quality using shunt active power filter. The proposedtopic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is fromhysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. Thispaper represe...

متن کامل

Applicability improvement and hysteresis current control method simplification in shunt active filters

Hysteresis current control method is vastly used in PWM inverters because of simplicity in performance, fast control response and good ability in limiting peak current. However, switching frequency in hysteresis current control method with fixed bandwidth has large variation during a cycle and therefore causes non-optimal current ripple generation in output current. One of basic problems in imp...

متن کامل

A Novel Fuzzy Variable-Band Hysteresis Current Controller For Shunt Active Power Filters

This paper presents a novel fuzzy control scheme applied to shunt active power filters for harmonic and reactive power compensation. A TSK type fuzzy logic controller is proposed for APF reference current generation. To control the maximum switching frequency of the converter within limit a novel fuzzy hysteresis band current controller is used. The band height, based on fuzzy control principle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Automatica

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2007