Effect of a volumatic spacer and mouth rinsing on systemic absorption of inhaled corticosteroids from a metered dose inhaler and dry powder inhaler.

نویسندگان

  • O Selroos
  • M Halme
چکیده

BACKGROUND High doses of inhaled corticosteroids are absorbed systemically and may cause long term side effects. As rinsing the mouth out after use and inhaling through a spacing device may reduce systemic absorption this has been further investigated. METHODS Three crossover studies were carried out to assess the effect of budesonide given by dry powder inhaler (Turbuhaler) with and without mouth rinsing and beclomethasone dipropionate given by metered dose inhaler with or without a spacing device (Volumatic) on serum cortisol concentrations and urinary cortisol excretion in patients with asthma taking an inhaled corticosteroid. Each treatment period was two weeks with in a two week washout period. Serum cortisol concentrations at 0800 hours on day 14 and the 24 hour urinary excretion of cortisol were measured. In study 1 24 patients taking beclomethasone dipropionate 500 micrograms twice a day inhaled with (n = 10) or without (n = 14) a Volumatic spacing device were switched to a budesonide dry powder inhaler, 600 micrograms to be taken twice a day without mouth rinsing. In study 2 10 patients took budesonide 800 micrograms twice a day with and without mouth rinsing and without swallowing the rinsing water. In study 3 17 patients took budesonide 800 micrograms twice daily with mouth rinsing and beclomethasone dipropionate 500 micrograms twice daily with the spacing device and mouth rinsing. RESULTS In study 1 no difference was seen between budesonide without mouth rinsing and beclomethasone dipropionate without a spacer: beclomethasone with spacer caused less suppression of cortisol (mean (SD) serum cortisol concentration: beclomethasone and spacer 487(148), budesonide 368(145) nmol/l). In study 2 mouth rinsing caused less suppression of morning serum cortisol concentrations (rinsing 440(63), no rinsing 375(56) nmol/1). In study 3 there was no difference in serum or urinary cortisol concentrations between twice daily beclomethasone dipropionate 500 micrograms inhaled by Volumatic spacer or budesonide by Turbuhaler 800 micrograms twice daily, both with mouth rinsing. Individual serum cortisol values were within the normal range in all patients except one in study 1. CONCLUSION Systemic absorption of a corticosteroid inhaled from a metered dose inhaler is reduced by using a spacing device and that from a dry powder inhaler by mouth rinsing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of large volume spacer, breath-activated and dry powder inhalers in older people.

AIMS To see if elderly people can use the breath-activated (Easi-breathe) and dry powder (Turbohaler) inhalers as effectively as the metered-dose inhaler and Volumatic system. METHODS 102 inhaler-naive patients (aged 75-101, mean 84 years), without cognitive impairment, were randomly allocated one of Easi-breathe, Turbohaler or metered-dose inhaler and Volumatic placebo inhalers. Standardized...

متن کامل

Systemic activity of inhaled and swallowed beclomethasone dipropionate and the effect of different inhaler devices.

Inhaled glucocorticoids such as beclomethasone dipropionate, which are used in the treatment of asthma, may be associated with systemic adverse effects. To determine whether any systemic absorption following the inhalation of beclomethasone was a result of drug being absorbed from the lung (inhaled fraction) or the gastrointestinal tract (swallowed fraction), we studied normal subjects after th...

متن کامل

Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.

OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...

متن کامل

Relative bioavailability of salbutamol to the lung following inhalation using metered dose inhalation methods and spacer devices.

BACKGROUND Inhalation aids do not require coordination between actuation of a metered dose inhaler (MDI) with inspiration and reduce oropharyngeal impaction. The delivery of salbutamol to the lung and systemic availability following inhalation with three commonly used spacers and an open mouth technique have been evaluated using a simple noninvasive technique based on urinary excretion 30 minut...

متن کامل

Volumatic usage: some generic salbutamol metered dose inhalers can be used.

BACKGROUND The 30 minute and 24 hour post-inhalation urinary excretion of salbutamol represents the relative amount of drug deposited in the lungs and total systemic absorption, respectively. Using this method two metered dose inhalers used with a Volumatic (Allen and Hanburys Ltd, UK) large volume spacer have been compared. METHOD Eleven healthy volunteers inhaled 4 x 100 micrograms salbutam...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 46 12  شماره 

صفحات  -

تاریخ انتشار 1991