Assessment of Osstell ISQ’s reliability for implant stability measurement: A cross-sectional clinical study

نویسندگان

  • Mariano Herrero-Climent
  • Rocio Santos-García
  • Reyes Jaramillo-Santos
  • Manuel M. Romero-Ruiz
  • Ana Fernández-Palacin
  • Pedro Lázaro-Calvo
  • Pedro Bullón
  • Jose V. Ríos-Santos
چکیده

UNLABELLED Resonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. OBJECTIVE Assess the Osstell ISQ system's reliability (i.e., its measurement reproducibility and repeatability) by means of the intraclass correlation coefficient (ICC) as statistical method. DESIGN OF THE STUDY Two implant stability registers were completed by means of Osstell ISQ on 85 implants on 23 patients. Six measurements were completed on each implant by means of two different SmartPegs (types I and II); that is, three consecutive measurements with each transducer. RESULTS Average ISQ was 72.40, 72.22 and 72.79, and 72.06, 72.59 and 72.82 in the first, second, and third measurements with SmartPegs I and II, respectively. Equal values or differences below three ISQ points were observed in 52.9% and 62.4% of the cases with SmartPegs I and II, respectively. The intraclass correlation coefficient was 0.97 for both SmartPegs, and repeatability and reproducibility also reached 0.97 for both SmartPegs. CONCLUSIONS The RFA system Osstell ISQ presents almost perfect repeatability and reproducibility after intraclass correlation coefficient analysis. Osstell ISQ measurements are highly reliable regarding reproducibility. Therefore, one measurement proves enough.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis of implant stability and its impact on implant survival: a prospective case series study.

OBJECTIVES To assess the predictability of implant stability assessment either clinically or by resonance frequency analysis (RFA). MATERIAL AND METHODS This prospective case series study evaluated 4114 consecutive SLA Straumann implants in two private clinics. Primary stability was classified in four categories, depending on the degree of implant rotation when tightening the healing cap: A (...

متن کامل

Comparative analysis of 2 resonance frequency measurement devices: Osstell Mentor and Osstell ISQ.

OBJECTIVE Comparing reliability of Osstell Mentor and Osstell ISQ in implant stability measurement, and assessing whether their measurements are comparable. MATERIALS AND METHOD Implant stability was measured with both devices on 58 implants in 15 patients. Six measurements were completed with each device with 2 different transducers (3 measurements with each transducer), that is, 12 measurem...

متن کامل

A comparative study on the accuracy of the devices for measuring the implant stability

STATEMENT OF PROBLEM How the ISQ values measured by Osstell™ and Osstell™ Mentor are related, and whether the ISQ values acquired from the two machines changes in accordance with changes in implant stability are not yet fully understood. PURPOSE The aim of this study was to find out correlation between the ISQ values acquired from Osstell™ and Osstell™ Mentor, and to evaluate the clinical eff...

متن کامل

ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency

BACKGROUND Implant stability testing at various stages of implant therapy by means of resonance frequency analysis is extensively used. The overall measurement outcome is a function of the resulting stiffness of three entities: surrounding bone, bone-implant complex, and implant-Smartpeg complex. The influence of the latter on the overall measurement results is presently unknown. It can be inve...

متن کامل

Resonance frequency analysis-reliability in third generation instruments: Osstell mentor®

UNLABELLED Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). OBJECTIVE Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2013