Effect of leak and breathing pattern on the accuracy of tidal volume estimation by commercial home ventilators: a bench study.
نویسندگان
چکیده
BACKGROUND New home ventilators are able to provide clinicians data of interest through built-in software. Monitoring of tidal volume (VT) is a key point in the assessment of the efficacy of home mechanical ventilation. OBJECTIVE To assess the reliability of the VT provided by 5 ventilators in a bench test. METHODS Five commercial ventilators from 4 different manufacturers were tested in pressure support mode with the help of a breathing simulator under different conditions of mechanical respiratory pattern, inflation pressure, and intentional leakage. Values provided by the built-in software of each ventilator were compared breath to breath with the VT monitored through an external pneumotachograph. Ten breaths for each condition were compared for every tested situation. RESULTS All tested ventilators underestimated VT (ranges of -21.7 mL to -83.5 mL, which corresponded to -3.6% to -14.7% of the externally measured VT). A direct relationship between leak and underestimation was found in 4 ventilators, with higher underestimations of the VT when the leakage increased, ranging between -2.27% and -5.42% for each 10 L/min increase in the leakage. A ventilator that included an algorithm that computes the pressure loss through the tube as a function of the flow exiting the ventilator had the minimal effect of leaks on the estimation of VT (0.3%). In 3 ventilators the underestimation was also influenced by mechanical pattern (lower underestimation with restrictive, and higher with obstructive). CONCLUSIONS The inclusion of algorithms that calculate the pressure loss as a function of the flow exiting the ventilator in commercial models may increase the reliability of VT estimation.
منابع مشابه
Effect of dynamic random leaks on the monitoring accuracy of home mechanical ventilators: a bench study
BACKGROUND So far, the accuracy of tidal volume (VT) and leak measures provided by the built-in software of commercial home ventilators has only been tested using bench linear models with fixed calibrated and continuous leaks. The objective was to assess the reliability of the estimation of tidal volume (VT) and unintentional leaks in a single tubing bench model which introduces random dynamic ...
متن کاملبررسی نیازهای توجهی کنترل الگوی تنفس و ارتباط آن با پیامدهای متابولیکی تنفس در افراد سالم
Objective: Normal breathing is essential for adjustment of natural metabolism of human body. Therefore, the aim of this study was to evaluate the control of breathing pattern in normal subjects both at rest and during cognitive loading. Materials & Methods: In this quasi-experimental study, 24 healthy subjects (14 males, 10 females) were selected by simple and convenient sampling. Spirometry...
متن کاملInfluence of dynamic leaks in volume-targeted pressure support noninvasive ventilation: a bench study.
INTRODUCTION The effect of leaks on volume-targeted pressure support noninvasive ventilation mode has only been tested with continuous simulated leaks. The objective of the study was to assess the influence of random leaks occurring either during inspiration or expiration. METHODS Analysis of the volume-targeted pressure support mode in 6 commercial ventilators with single-limb circuits and i...
متن کاملA bench study of the effects of leak on ventilator performance during noninvasive ventilation.
BACKGROUND During noninvasive ventilation (NIV), leak around the mask may cause inadequate ventilatory support or patient-ventilator asynchrony such as auto-triggering. Some NIV ventilators may be better than others at compensating for leak. METHODS We bench studied 3 NIV ventilators (Vision, Carina, and Trilogy100) and 2 ICU ventilators (Puritan Bennett 840 and Evita XL) to assess how they ...
متن کاملNear-infrared spectroscopy with vascular occlusion test may not be the adequate tool to explore microcirculation in pulmonary arterial hypertension.
essentials of respiratory care, 4th edition. St. Louis:Mosby Elsevier; 2005:103. 13. L’Her E, Roy A. Bench tests of simple, handy ventilators for pandemics: performance, autonomy, and ergonomy. Respir Care 2011;56(6):751-760. 14. Lyazidi A, Thille AW, Carteaux G, Galia F, Brochard L, Richard JC. Bench test evaluation of volume delivered by modern ICU ventilators during volume-controlled ventila...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 58 5 شماره
صفحات -
تاریخ انتشار 2013