Maternal and neonatal factors associated with meconium stained amniotic fluid

نویسندگان

  • Uzma Firdaus
  • Sandeep Sachdeva
چکیده

The study was conducted to study the clinical profile of babies and their mothers with meconium stained amniotic fluid at birth. All babies born with meconium stained amniotic fluid (MSAF) at Jawaharlal Nehru Medical College Hospital, Aligarh Muslim University Aligarh from July2010 to December 2010 were included in the study. Out of 172 babies with MSAF, 31 developed Meconium Aspiration Syndrome (MAS)while 141 did not. For both the groups, the case records of the babies and their mothers were retrospectively studied and compared using univariate analysis and multiple regression analysis. The incidence of MSAF was 9.8% and of MAS was around 1.8%.The characteristics of the babies associated with increased risk of MAS were low Apgar score at 5 minutes and presence of respiratory distress soon after birth. No significant maternal risk factor was identified. Practising standard delivery guidelines, meticulous resuscitation at birth and vigilant monitoring of distressed babies immediately following birth may bring down the incidence of MAS. KEYWORDSMeconium Stained Amniotic fluid, (MSAF), Meconium Aspiration Syndrome (MAS) Accepted October 27 2012

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Comparison of Maternal Endometritis in Meconium – Stained Amniotic Fluid and Clear Amniotic Fluid

Introduction: Metritis is one of the causes of maternal morbidity and there are many risk factors for it. Because of the importance of possible association of meconium-stained amniotic fluid and maternal metritis the present study was done to determine whether meconium stained amniotic fluid (MSAF) is associated with puerperal infection. Methods: In this case-control study 150 women with MSAF a...

متن کامل

Study of prognostic factors for meconium-stained amniotic fluid

Introduction: meconium is the thick, Green - Black, with a bad odor material,  that founded around the third month of pregnancy in the intestines of fetus. 8 to 15 percent of infants has the evidence of meconium stained fluid at birth. In this study the factors affecting maternal and neonatal meconium-stained amniotic fluid be examined. Methods: This study was done in the Vali-e- asr hospital ...

متن کامل

[Meconium-stained amniotic fluid and maternal and neonatal factors associated].

OBJECTIVE To identify the frequency and maternal and neonatal factors associated with meconium-stained amniotic fluid at birth. METHODS Cross-sectional study carried out with 2,441 births at an in-hospital birth center in the city of São Paulo (Southeastern Brazil) in March and April, 2005. The association between meconium-stained amniotic fluid and the independent variables (maternal age, pa...

متن کامل

Comparison of Neonatal Outcome with Meconium-Stained Amniotic Fluid in Normal Vaginal Delivery and Cesarean Section

Background and Objectives: Given the consequences and serious dangers, which threatens neonates born with meconium-stained amniotic fluid, and also due to the high prevalence of cesarean section, the present research was carried out with the aim of comparing the outcomes of neonates with meconium - stained amniotic fluid in vaginal delivery and cesarean section.   Methods: The present study wa...

متن کامل

بررسی عوامل خطرزای مادری و عوارض نوزادی در زایمان با مایع آمنیوتیک آغشته به مکونیوم و مایع آمنیوتیک شفاف

Background and Objective: Meconium Stained Amniotic Fluid (MSAF) is a common finding in term and post term pregnancies which has been taken into account as an unfavorable predictor of fetal and neonatal outcome. The aim of this study was to identify some maternal risk factors and neonatal complications in term pregnancies with meconium stained and clear amniotic fluid in Rasht Al Zahra Hospital...

متن کامل

Study on risk factors of meconium stained amniotic fluid and comparison of pregnancy outcome in clear and meconium stained amniotic fluid in a tertiary hospital, Kolkata, India

Keywords: Meconium stained amniotic fluid (MSAF) Pregnancy outcome Clear amniotic fluid (CAF) Original Article Objectives: To identify risk factors for meconium stained amniotic fluid (MSAF) and comparison of pregnancy outcome in meconium stained vs. clear amniotic fluid. Methods: The study was conducted at labor-room of IPGMER Hospital, Kolkata for consecutive 500 singleton deliveries at term ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012